Predicting preload responsiveness using simultaneous recordings of inferior and superior vena cavae diameters.

Charbonneau Hélène, Riu Béatrice, Faron Matthieu, Mari Arnaud, Kurrek Matt M, Ruiz Jean, Geeraerts Thomas, Fourcade Olivier, Genestal Michèle, Silva Stein

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

INTRODUCTION

Echocardiographic indices based on respiratory variations of superior and inferior vena cavae diameters (ΔSVC and ΔIVC, respectively) have been proposed as predictors of fluid responsiveness in mechanically ventilated patients, but they have never been compared simultaneously in the same patient sample. The aim of this study was to compare the predictive value of these echocardiographic indices when concomitantly recorded in mechanically ventilated septic patients.

METHODS

Septic shock patients requiring hemodynamic monitoring were prospectively enrolled over a 1-year period in a mixed medical surgical ICU of a university teaching hospital (Toulouse, France). All patients were mechanically ventilated. Predictive indices were obtained by transesophageal and transthoracic echocardiography and were calculated as follows: (Dmax - Dmin)/Dmax for ΔSVC and (Dmax - Dmin)/Dmin for ΔIVC, where Dmax and Dmin are the maximal and minimal diameters of SVC and IVC. Measurements were performed at baseline and after a 7-ml/kg volume expansion using a plasma expander. Patients were separated into responders (increase in cardiac index ≥15%) and nonresponders (increase in cardiac index <15%).

RESULTS

Among 44 included patients, 26 (59%) patients were responders (R). ΔSVC was significantly more accurate than ΔIVC in predicting fluid responsiveness. The areas under the receiver operating characteristic curves for ΔSVC and ΔIVC regarding assessment of fluid responsiveness were significantly different (0.74 (95% confidence interval (CI): 0.59 to 0.88) and 0.43 (95% CI: 0.25 to 0.61), respectively (P = 0.012)). No significant correlation between ΔSVC and ΔIVC was found (r = 0.005, P = 0.98). The best threshold values for discriminating R from NR was 29% for ΔSVC, with 54% sensitivity and 89% specificity, and 21% for ΔIVC, with 38% sensitivity and 61% specificity.

CONCLUSIONS

ΔSVC was better than ΔIVC in predicting fluid responsiveness in our cohort. It is worth noting that the sensitivity and specificity values of ΔSVC and ΔIVC for predicting fluid responsiveness were lower than those reported in the literature, highlighting the limits of using these indices in a heterogeneous sample of medical and surgical septic patients.

Для цитирования: Charbonneau Hélène, Riu Béatrice, Faron Matthieu, Mari Arnaud, Kurrek Matt M, Ruiz Jean, Geeraerts Thomas, Fourcade Olivier, Genestal Michèle, Silva Stein. Predicting preload responsiveness using simultaneous recordings of inferior and superior vena cavae diameters.. Critical care (London, England). 2014. DOI: 10.1186/s13054-014-0473-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.