Low dose of hydroxyethyl starch impairs clot formation as assessed by viscoelastic devices.

Tynngård Nahreen, Berlin Gösta, Samuelsson Anders, Berg Sören

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

High doses of the synthetic colloid hydroxyethyl starch (HES) used for plasma expansion have been associated with impaired haemostasis and hypocoagulation. Less is known about effects on clot formation in the low haemodilutional range (< 40%). This study evaluated the effects of low haemodilution with HES and albumin on coagulation using two different viscoelastic methods.

METHODS

Clot formation was studied in vitro in healthy donor blood after 10% and 30% haemodilution with 60 g/L HES 130/0.4 or 50 g/L albumin with free oscillation rheometry (FOR) and rotational thromboelastography.

RESULTS

Clotting time was not significantly affected at 10% haemodilution but was prolonged with both substances at 30% dilution (p < 0.01-0.001). The effect was significantly more pronounced with HES than with albumin. The elasticity of the clot was slightly reduced at 10% dilution with albumin, more pronounced at 10% dilution with HES (p < 0.05), further reduced at 30% dilution with albumin and to a still greater extent at 30% dilution with HES (p < 0.05). With albumin the functional activity of fibrinogen was not reduced in excess of the dilutional effect. HES in contrast produced a further reduction in clot elasticity than caused by mere dilution at both 10% and 30% dilutions (p < 0.001).

CONCLUSIONS

There is an adverse effect on clot formation even at low grade haemodilution with both albumin and HES. The effect on coagulation is significantly more pronounced with HES than with albumin.

Для цитирования: Tynngård Nahreen, Berlin Gösta, Samuelsson Anders, Berg Sören. Low dose of hydroxyethyl starch impairs clot formation as assessed by viscoelastic devices.. Scandinavian journal of clinical and laboratory investigation. 2014. DOI: 10.3109/00365513.2014.891259.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.