Journal of pharmacy practice · 2012
Albumin utilization in cardiac surgery after transition to hydroxyethyl starch 130/0.4.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Romerill David B, Toyoda Alexander Y, Brodeur Brandon E, Moellentin Daniel
Аннотация
OBJECTIVE: Evaluate the impact of replacing hydroxyethyl starch (HES) 670/0.75 with lower molecular weight HES 130/0.4 on albumin utilization in cardiac surgery, as well as any impact on renal function and bleeding.
DESIGN: A pre- and postimplementation, retrospective analysis.
SETTING: Community, not-for-profit, tertiary medical center.
PARTICIPANTS: One hundred forty-six patients undergoing nonemergent cardiac bypass graft and cardiac valve surgeries after exclusion for documented anemia, malignancy, coagulation disorder, end-stage renal disease, or personal objection to receiving blood products.
INTERVENTION: HES 130/0.4 utilization instead of HES 670/0.75 for volume expansion.
MEASUREMENTS AND MAIN RESULTS: Patients were less likely to be administered albumin intraoperatively (odds ratio [OR] 0.16, confidence interval [CI] 0.08-0.35, P < .001). When albumin was utilized, intraoperative amounts were similar (mean ± standard deviation [SD]: 36.1 ± 17.1 g vs 43.8 ± 15.5 g, P = .16). Patients were more likely to receive an intraoperative HES product after the formulary change (OR 11.1, CI 4.4-27.6, P < .001) as well as larger volumes (mean ± SD: 743 ± 544 mL vs 500 ± 0 mL, P = .01). No differences were detected in mean baseline-to-discharge changes in serum creatinine or in postoperative urine output, nor were there differences in clinically significant bleeding.
CONCLUSIONS: Change to a lower molecular weight HES decreased intraoperative albumin utilization and increased HES utilization with no detected difference in renal function or bleeding complications.
DESIGN: A pre- and postimplementation, retrospective analysis.
SETTING: Community, not-for-profit, tertiary medical center.
PARTICIPANTS: One hundred forty-six patients undergoing nonemergent cardiac bypass graft and cardiac valve surgeries after exclusion for documented anemia, malignancy, coagulation disorder, end-stage renal disease, or personal objection to receiving blood products.
INTERVENTION: HES 130/0.4 utilization instead of HES 670/0.75 for volume expansion.
MEASUREMENTS AND MAIN RESULTS: Patients were less likely to be administered albumin intraoperatively (odds ratio [OR] 0.16, confidence interval [CI] 0.08-0.35, P < .001). When albumin was utilized, intraoperative amounts were similar (mean ± standard deviation [SD]: 36.1 ± 17.1 g vs 43.8 ± 15.5 g, P = .16). Patients were more likely to receive an intraoperative HES product after the formulary change (OR 11.1, CI 4.4-27.6, P < .001) as well as larger volumes (mean ± SD: 743 ± 544 mL vs 500 ± 0 mL, P = .01). No differences were detected in mean baseline-to-discharge changes in serum creatinine or in postoperative urine output, nor were there differences in clinically significant bleeding.
CONCLUSIONS: Change to a lower molecular weight HES decreased intraoperative albumin utilization and increased HES utilization with no detected difference in renal function or bleeding complications.