Detection of right ventricular insufficiency and guidance of volume therapy are facilitated by simultaneous monitoring of static and functional preload parameters.

Richter Hans Peter, Petersen Christian, Goetz Alwin E, Reuter Daniel A, Kubitz Jens C

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Acute right ventricular failure (RVF) is a life-threatening condition. This study investigated whether the combination of central venous pressure (CVP) and left ventricular functional preload parameters, such as stroke volume variation (SVV) and pulse pressure variation (PPV), can be used for the detection of acute RVF and for guidance of volume therapy.

DESIGN AND

SETTING

Experimental study in a university laboratory.

PARTICIPANTS

Fifteen anesthetized and ventilated pigs.

MEASUREMENTS AND MAIN

RESULTS

For the induction of RVF, mean pulmonary artery pressure (MPAP) was increased by 50% with a continuous infusion of a thromboxane-A(2) analog (U46619). Then, blood removal (300 mL) and retransfusion (blood 200 mL + colloid solution 200 mL) were performed. An analysis of volume responders and nonresponders was implemented. Increasing MPAP (25.1 to 37.4 mmHg) led to decreases in mean arterial pressure (72.2 to 60.1 mmHg) and cardiac output (2.8 to 2.3 L/min, p < 0.05). CVP (11.3 to 12.6 mmHg), PPV (13% to 17%), and SVV (11 to 14%) increased significantly (p < 0.05). During volume removal, MPAP (37.4 to 34.1 mmHg), mean arterial pressure (60.1 to 53.2 mmHg), and cardiac output (2.3 to 2.1 L/min) decreased (p < 0.05), whereas PPV and SVV remained unchanged. During volume loading, CVP increased in volume responders and nonresponders; however, PPV decreased in responders only.

CONCLUSIONS

Increases of CVP and SVV or PPV are suspicious for RVF. However, SVV and PPV fail to predict volume responsiveness in RVF. Changes in SVV and PPV during a volume-loading maneuver can be used to assess volume responsiveness.

Для цитирования: Richter Hans Peter, Petersen Christian, Goetz Alwin E, Reuter Daniel A, Kubitz Jens C. Detection of right ventricular insufficiency and guidance of volume therapy are facilitated by simultaneous monitoring of static and functional preload parameters.. Journal of cardiothoracic and vascular anesthesia. 2011. DOI: 10.1053/j.jvca.2011.07.016.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.