An increase in aortic blood flow after an infusion of 100 ml colloid over 1 minute can predict fluid responsiveness: the mini-fluid challenge study.

Muller Laurent, Toumi Medhi, Bousquet Philippe-Jean, Riu-Poulenc Béatrice, Louart Guillaume, Candela Damien, Zoric Lana, Suehs Carey, de La Coussaye Jean-Emmanuel, Molinari Nicolas, Lefrant Jean-Yves, AzuRéa Group

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Predicting fluid responsiveness remains a difficult question in hemodynamically unstable patients. The author's objective was to test whether noninvasive assessment by transthoracic echocardiography of subaortic velocity time index (VTI) variation after a low volume of fluid infusion (100 ml hydroxyethyl starch) can predict fluid responsiveness.

METHODS

Thirty-nine critically ill ventilated and sedated patients with acute circulatory failure were prospectively studied. Subaortic VTI was measured by transthoracic echocardiography before fluid infusion (baseline), after 100 ml hydroxyethyl starch infusion over 1 min, and after an additional infusion of 400 ml hydroxyethyl starch over 14 min. The authors measured the variation of VTI after 100 ml fluid (ΔVTI 100) for each patient. Receiver operating characteristic curves were generated for (ΔVTI 100). When available, receiver operating characteristic curves also were generated for pulse pressure variation and central venous pressure.

RESULTS

After 500 ml volume expansion, VTI increased ≥ 15% in 21 patients (54%) defined as responders. ΔVTI 100 ≥ 10% predicted fluid responsiveness with a sensitivity and specificity of 95% and 78%, respectively. The area under the receiver operating characteristic curves of ΔVTI 100 was 0.92 (95% CI: 0.78-0.98). In 29 patients, pulse pressure variation and central venous pressure also were available. In this subgroup of patients, the area under the receiver operating characteristic curves for ΔVTI 100, pulse pressure variation, and central venous pressure were 0.90 (95% CI: 0.74-0.98, P < 0.05), 0.55 (95% CI: 0.35-0.73, NS), and 0.61 (95% CI: 0.41-0.79, NS), respectively.

CONCLUSION

In patients with low volume mechanical ventilation and acute circulatory failure, ΔVTI 100 accurately predicts fluid responsiveness.

Для цитирования: Muller Laurent, Toumi Medhi, Bousquet Philippe-Jean, Riu-Poulenc Béatrice, Louart Guillaume, Candela Damien, Zoric Lana, Suehs Carey, de La Coussaye Jean-Emmanuel, Molinari Nicolas, Lefrant Jean-Yves, AzuRéa Group. An increase in aortic blood flow after an infusion of 100 ml colloid over 1 minute can predict fluid responsiveness: the mini-fluid challenge study.. Anesthesiology. 2011. DOI: 10.1097/aln.0b013e318229a500.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.