MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1053/j.jvca.2009.09.014

Медицинская библиотека · Journal of cardiothoracic and vascular anesthesia · 2009

A new plasma-adapted hydroxyethyl starch preparation: in vitro coagulation studies.

Boldt Joachim, Mengistu Andinet

СтатьяРандомизированное исследованиеОтозванная публикацияПеревод в очереди
Источник пометил публикацию как отозванную.

Аннотация

OBJECTIVE

Preparing hydroxyethyl starch (HES) in a plasma-adapted solution is supposed to improve safety with regard to coagulation. The influence of a new plasma-adapted HES preparation on coagulation was studied.

DESIGN

Operator-blinded, randomized study.

SETTING

Laboratory in vitro study.

PARTICIPANTS

Fifteen healthy young men scheduled for blood donation.

INTERVENTIONS: Blood was diluted by 10%, 30%, and 50% using either a plasma-adapted or nonplasma-adapted (prepared in saline solution) potato-derived 6% HES 130/0.42. Only the composition of the solvent of the 2 HES preparations was different.

MEASUREMENTS AND MAIN

RESULTS

Rotation thromboelastometry (ROTEM; Pentapharm, Munich, Germany) was used to assess changes in coagulation; whole blood aggregometry with 3 inducers was used to assess effects of dilution with HES on platelet function. Clotting time (CT) and clot formation time were significantly prolonged by 30% and 50% dilution, showing significantly longer times in the non-plasma-adapted than in the plasma-adapted HES group (eg, intrinsic CT at the 30% dilution level: plasma-adapted HES 228 +/- 26 seconds [within normal range] v 269 +/- 29 seconds in the nonplasma-adapted HES group). Clot strengthening and clot firmness were significantly reduced by the non-plasma-adapted HES at the 30% dilution level. Platelet aggregation was significantly more reduced by the non-plasma-adapted HES at the 30% and 50% dilution levels.

CONCLUSIONS

Dilution with the nonplasma-adapted HES 130/0.42 was associated with more negative effects on thromboelastometry and platelet aggregation than the same HES 130/0.4 dissolved in a plasma-adapted solution. The benefits of using a plasma-adapted modern HES preparation on blood loss and use of blood/blood products in cardiac surgery need to be studied.

Для цитирования: Boldt Joachim, Mengistu Andinet. A new plasma-adapted hydroxyethyl starch preparation: in vitro coagulation studies.. Journal of cardiothoracic and vascular anesthesia. 2009. DOI: 10.1053/j.jvca.2009.09.014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.