Colloid preload versus coload for spinal anesthesia for cesarean delivery: the effects on maternal cardiac output.

Teoh Wendy H L, Sia Alex T H

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Spinal anesthesia for cesarean delivery may cause severe maternal hypotension, and a decrease in cardiac output (CO) and blood flow to the placenta. Fluid preloading with crystalloid is ineffective due to rapid redistribution. A "coload" given at the time of cerebrospinal fluid identification may be more effective. Our null hypothesis was that there would be no difference between the effect of a colloid preload (15 mL/kg hydroxyethyl starch (HES) 130/0.4 [Voluven 6%]) and an identical coload on maternal CO and the incidence of hypotension after spinal anesthesia for cesarean delivery. Secondary outcomes studied were neonatal acid- base status and predelivery vasopressor requirements.

METHODS

Forty ASA PS I and II women scheduled for elective cesarean delivery were recruited. Patients were randomized to Group P (preload of 15 mL/kg HES) or Group C (coload, given when cerebrospinal fluid identified). Heart rate, arterial blood pressure, stroke volume and CO measurements were recorded at baseline, every minute for 10 min, and every 2.5 min interval for 10 min with the USCOM ultrasonic CO monitor. Spinal anesthesia was performed at the L3/4 interspace in the right lateral position. Arterial blood pressure was maintained at 90%-100% of baseline values using IV phenylephrine boluses.

RESULTS

Demographic, anesthetic, and surgical characteristics were similar. There were no between-group differences in baseline systolic blood pressure, heart rate, and colloid volume. CO and stroke volume were significantly increased in Group P (P = 0.01) in the 5 min after spinal anesthesia. This increase in CO was not sustained at 10 min. There were no significant between-group differences in the incidence of hypotension, absolute arterial blood pressure values (P = 0.73), predelivery median (range) phenylephrine requirements (300[0-1000] in Group P versus 150 [0-850]microg in Group C, P = 0.24), or neonatal outcome as measured by Apgar scores and umbilical arterial and venous blood gas values.

CONCLUSION

Intravascular volume expansion with 15 mL/kg HES 130/0.4 given as a preload, but not coload, significantly increased maternal CO for the first 5 min after spinal anesthesia for cesarean delivery, however, maternal and neonatal outcomes were not different.

Для цитирования: Teoh Wendy H L, Sia Alex T H. Colloid preload versus coload for spinal anesthesia for cesarean delivery: the effects on maternal cardiac output.. Anesthesia and analgesia. 2009. DOI: 10.1213/ane.0b013e31819e016d.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.