MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/01.anes.0000265422.07864.37

Медицинская библиотека · Anesthesiology · 2007

Volume replacement therapy during major orthopedic surgery using Voluven (hydroxyethyl starch 130/0.4) or hetastarch.

Gandhi Sweeta D, Weiskopf Richard B, Jungheinrich Cornelius, Koorn Robert, Miller Diane, Shangraw Robert E, Prough Donald S, Baus Daniela, Bepperling Frank, Warltier David C

СтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

The purpose of this study was to test the equivalence of efficacy and compare the safety of the 6% hydroxyethyl starches (HES) Voluven (HES 130/0.4; Fresenius Kabi, Bad Homburg, Germany) and hetastarch (HES 670/0.75 in saline) for intravascular volume replacement therapy during major orthopedic surgery.

METHODS

In a prospective, controlled, randomized, double-blind, multicenter trial of patients undergoing major orthopedic surgery, 49 patients were treated with HES 130/0.4 and 51 patients were treated with hetastarch. Infusion of colloids was guided by central venous and arterial blood pressures. The primary efficacy endpoint was the volume of colloid solution infused; the primary safety endpoints were calculated total erythrocyte loss, the nadir factor VIII activity, and the nadir von Willebrand factor concentration within 2 h of completion of surgery.

RESULTS

The total volume of colloid solution required for intraoperative volume replacement did not differ between HES 130/0.4 and hetastarch (1,613+/-778 [SD] ml for HES 130/0.4 and 1,584+/-958 ml for hetastarch). The nadir factor VIII activity within 2 h of the end of surgery was lower for hetastarch than for HES 130/0.4 (P=0.0499); for those who received greater than 1,000 ml colloid, the nadir factor VIII activity and von Willebrand factor concentration within 2 h of end of surgery were lower for hetastarch than for HES 130/0.4 (P=0.0487 and P=0.008, respectively).

CONCLUSION

Voluven (HES 130/0.4) and hetastarch are equally efficacious plasma volume substitutes; however, HES 130/0.4 has a lesser effect on coagulation.

Для цитирования: Gandhi Sweeta D, Weiskopf Richard B, Jungheinrich Cornelius, Koorn Robert, Miller Diane, Shangraw Robert E, Prough Donald S, Baus Daniela, Bepperling Frank, Warltier David C. Volume replacement therapy during major orthopedic surgery using Voluven (hydroxyethyl starch 130/0.4) or hetastarch.. Anesthesiology. 2007. DOI: 10.1097/01.anes.0000265422.07864.37.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.