m+Medelevator.RU
← Поиск публикаций
Chirurgia (Bucharest, Romania : 1990) · 2006

[A comparison between systolic pressure variations under mechanical ventilation and classic pressure parameters in predicting fluid responsiveness in patients after coronary surgery].

Клиническое исследованиеСравнительное исследованиеАннотация на английскомСтатьяМногоцентровое исследованиеРандомизированное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Bubenek S, Giurgiuman Luminiţa, Miclea I, Boros C, Iliescu V, Vasile R

Аннотация

Evaluation of the value of the systolic pressure variations (SPV) under mechanical ventilation and of its components (delta down and delta up) in predicting fluid responsiveness in patients after coronary surgery by comparison with classic parameters. A prospective,randomized study, on 50 patients who underwent CABG surgery, in the early postoperative period (the first two hours). We assessed the following parameters: CO, CI, CVP, PCWP, SAP, DAP, MAP, SVP, delta down and delta up. The including criteria were: sinus rhythm, CI < or = 2,5 l/min/m2, PCP < 18 mmHg. All the patients underwent a fluid challenge (500 ml of colloids in 10 min). Three patients were excluded: 3 for a PCWP > 18 mm Hg, 1 for loosing the sinus rhythm and 1 for an early return in the OR for bleeding. After a new assessment of the same parameters the patients were divided in two groups: group A (28 pts) with a raise of CI > 15%, and group B (22 pts) with a CI variation < 15%. In each group was statistically analyzed the variation of each parameter. Results Both parameters provided by SPV analysis are able to predict the fluid responsiveness with a great accuracy: the positive predictive value of a SPV > 12 mmHg is above 92,85% and of a delta down > 5 mm Hg is above 96,42%; the negative predictive value of a SPV < or = 12 mmHg is above 90,90% and of a delta down = 5 mm Hg is above 95,45%. None of the "classic" pressure parameters (MAP, CVP, PCWP) used in hemodynamic assessment have revealed a statistical significant variation. The SVP method's parameters are superior to classic pressure parameters (MAP, CVP, PCWP) in predicting fluid responsiveness in patients after coronary surgery.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты