MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jamcollsurg.2005.05.031

Медицинская библиотека · Journal of the American College of Surgeons · 2005

Resuscitation with pressors after traumatic brain injury.

Feinstein Ara J, Patel Mayur B, Sanui Masamitsu, Cohn Stephen M, Majetschak Matthias, Proctor Kenneth G

Сравнительное исследованиеСтатьяПоддержка NIH: внешняя программаПоддержка правительства СШАПоддержка службы здравоохранения СШАПеревод в очереди

Аннотация

BACKGROUND

The purpose of the study was to compare initial resuscitation with arginine vasopressin (AVP), phenylephrine (PE), or isotonic crystalloid fluid alone after traumatic brain injury and vasodilatory shock.

STUDY

DESIGN

Anesthetized, ventilated swine (n = 39, 30 +/- 2 kg) underwent fluid percussion traumatic brain injury followed by hemorrhage (30 +/- 2mL/kg) to a mean arterial pressure < 30mmHg, then were randomized to 1 of 5 groups to maintain mean arterial pressure > 60mmHg for 30 to 60minutes, then cerebral perfusion pressure > 60mmHg for 60 to 300minutes, either unlimited crystalloid fluid only (n = 9), arginine vasopressin + fluid (n = 9), phenylephrine + fluid (n = 9), arginine vasopressin only (n = 5), or phenylephrine only (n = 5). Heterologous transfusions were administered if hematocrit was < 13, and mannitol was administered if intracranial pressure was > 20 mmHg. Cerebrovascular reactivity was evaluated with serial CO(2) challenges.

RESULTS

In all groups, physiologic variables were similar at baseline and at the end of shock. On resuscitation, all achieved mean arterial pressure and cerebral perfusion pressure goals. Brain tissue PO(2)s were similar. With fluid only, more blood and mannitol were required, intracranial pressure and peak inspiratory pressure were higher, and cerebrovascular reactivity was decreased (all p < 0.05 versus pressor + fluid). With either pressor + fluid, cardiac output, heart rate, lactate, and mixed venous O(2) saturation were similar to fluid only, but total fluid requirements and urine output were both reduced (p < 0.05). With either pressor only, intracranial pressure remained low, but mixed venous O(2) saturation, cardiac output, and urine output were decreased (all p < 0.05 versus other groups).

CONCLUSIONS

To correct vasodilatory shock after traumatic brain injury, a resuscitation strategy that combined either phenylephrine or arginine vasopressin plus crystalloid was superior to either fluid alone or pressor alone.

Для цитирования: Feinstein Ara J, Patel Mayur B, Sanui Masamitsu, Cohn Stephen M, Majetschak Matthias, Proctor Kenneth G. Resuscitation with pressors after traumatic brain injury.. Journal of the American College of Surgeons. 2005. DOI: 10.1016/j.jamcollsurg.2005.05.031.