MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00134-004-2176-x

Медицинская библиотека · Intensive care medicine · 2004

Crystalloid strong ion difference determines metabolic acid-base change during acute normovolaemic haemodilution.

Morgan Thomas J, Venkatesh Balasubramanian, Hall Jonathan

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To study the acid-base effects of crystalloid strong ion difference (SID) during haemodilution.

DESIGN

Prospective in vivo study.

SETTING

University laboratory.

SUBJECTS: Anaesthetised, mechanically ventilated Sprague-Dawley rats.

INTERVENTIONS: Rats were studied in seven groups of three. Each group underwent normovolaemic haemodilution with one of seven crystalloids, with SID values from 0 to 40 mEq/l. Six exchanges of 9 ml crystalloid for 3 ml blood were performed.

MEASUREMENTS AND MAIN

RESULTS

[Hb] fell from 142+/-17 to 44+/-10 g/l ( p<0.0001). Final plasma [lactate] was 1.1+/-0.6 mmol/l. Final standard base excess values ranged from -8 to +7 mmol/l, and were directly correlated with crystalloid SID (R(2)=0.91). By linear regression, the SID of a crystalloid balanced to maintain standard base excess=0 mmol/l was 23.7 mEq/l. Dilutions 2-5 produced similar results.

CONCLUSIONS

There is a linear relationship between crystalloid SID and post-dilutional metabolic acid-base status. The SID of a crystalloid balanced for normovolaemic haemodilution is 24 mEq/l. These principles are applicable in designing fluids for volume resuscitation, acute normovolaemic haemodilution and cardio-pulmonary bypass.

Для цитирования: Morgan Thomas J, Venkatesh Balasubramanian, Hall Jonathan. Crystalloid strong ion difference determines metabolic acid-base change during acute normovolaemic haemodilution.. Intensive care medicine. 2004. DOI: 10.1007/s00134-004-2176-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.