MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s1074-3804(05)60517-8

Медицинская библиотека · The Journal of the American Association of Gynecologic Laparoscopists · 2002

Prevention of adhesions with crystalloids during laparoscopic surgery in mice.

Elkelani Osama Ali, Molinas Carlos Roger, Mynbaev Ospan, Koninckx Philippe Robert

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

STUDY

OBJECTIVE

To evaluate the effect of saline and Ringer's lactate solutions in preventing adhesions during laparoscopic surgery in mice.

DESIGN

Prospective, randomized trial (Canadian Task Force classification I).

SETTING

Academic research center.

SUBJECTS: Ninety-two female Naval Medical Research Institute mice.

INTERVENTION: Adhesions were induced laparoscopically by opposing bipolar lesions in the uterine horns and pelvic sidewalls, and saline or Ringer's lactate solution was added at different times during the procedure.

MEASUREMENTS AND MAIN

RESULTS

Adhesions were scored quantitatively and qualitatively for extent, type, and tenacity after 7 days under microscopic vision during laparotomy. After 45 minutes of pneumoperitoneum, neither solution reduced adhesion formation, but when added immediately after surgery they did (p = 0.002). Coagulation was not significantly different with addition of either solution immediately after coagulation. In the third experiment the presence of fluid during pneumoperitoneum decreased adhesion formation (p = 0.0001) but Ringer's lactate was more effective than saline (p = 0.0005).

CONCLUSION

Crystalloids reduced CO(2) pneumoperitoneum-enhanced adhesion formation in a laparoscopic mouse model, but Ringer's lactate solution was more effective than saline.

Для цитирования: Elkelani Osama Ali, Molinas Carlos Roger, Mynbaev Ospan, Koninckx Philippe Robert. Prevention of adhesions with crystalloids during laparoscopic surgery in mice.. The Journal of the American Association of Gynecologic Laparoscopists. 2002. DOI: 10.1016/s1074-3804(05)60517-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.