Kinetics of isotonic and hypertonic plasma volume expanders.

Drobin Dan, Hahn Robert G

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Major differences in plasma volume expansion between infusion fluids are fairly well known, but there is a lack of methods that express their dynamic properties. Therefore, a closer description enabled by kinetic modeling is presented.

METHODS

Ten healthy male volunteers received, on different occasions, a constant-rate intravenous infusion over 30 min consisting of 25 ml/kg of 0.9% saline, lactated Ringer's solution, acetated Ringer's solution, 5 ml/kg of 7.5% saline, or 3 ml/kg of 7.5% saline in 6% dextran. One-, two-, and three-volume kinetic models were fitted to the dilution of the total venous hemoglobin concentration over 240 min. Osmotic fluid shifts were considered when hypertonic fluid was infused.

RESULTS

All fluids induced plasma dilution, which decreased exponentially after the infusions. The ratio of the area under the dilution-time curve and the infused fluid volume showed the following average plasma-dilution dose-effect (efficiency), using 0.9% saline as the reference (= 1): lactated Ringer's solution, 0.88; acetated Ringer's solution, 0.91; hypertonic saline, 3.97; and hypertonic saline in dextran, 7.22 ("area approach"). Another comparison, based on kinetic analysis and simulation, showed that the strength of the respective fluids to dilute the plasma by 20% within 30 min was 0.94, 0.97, 4.44, and 6.15 ("target dilution approach"). Between-subject variability was approximately half as high for the latter approach.

CONCLUSIONS

The relative efficiency of crystalloid infusion fluids differs depending on whether the entire dilution-time profile or only the maximum dilution is compared. Kinetic analysis and simulation is a useful tool for the study of such differences.

Для цитирования: Drobin Dan, Hahn Robert G. Kinetics of isotonic and hypertonic plasma volume expanders.. Anesthesiology. 2002. DOI: 10.1097/00000542-200206000-00016.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.