Swiss medical weekly · 2021
COVID-19 Inmate Risk Appraisal (CIRA): development and validation of a screening tool to assess COVID-19 vulnerability in prisons.
СтатьяВалидационное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Gonçalves Leonel Cunha, Baggio Stéphanie, Weber Michael, Gétaz Laurent, Wolff Hans, Singh Jay, Naegeli Andreas, Rossegger Astrid, Endrass Jérôme
Аннотация
OBJECTIVES: To develop and validate a screening tool designed to identify detained people at increased risk for COVID-19 mortality, the COVID-19 Inmate Risk Appraisal (CIRA).
DESIGN: Cross-sectional study with a representative sample (development) and a case-control sample (validation).
SETTING: The two largest Swiss prisons.
PARTICIPANTS: (1) Development sample: all male persons detained in Pöschwies, Zurich (n = 365); (2) Validation sample: case-control sample of male persons detained in Champ-Dollon, Geneva (n = 192, matching 1:3 for participants at risk for severe course of COVID-19 and participants without risk factors).
MAIN OUTCOME MEASURES: The CIRA combined seven risk factors identified by the World Health Organization and the Swiss Federal Office of Public Health as predictive of severe COVID-19 to derive an absolute risk increase in mortality rate: Age ≥60 years, cardiovascular disease, diabetes, hypertension, chronic respiratory disease, immunodeficiency and cancer.
RESULTS: Based on the development sample, we proposed a three-level classification: average (<3.7), elevated (3.7-5.7) and high (>5.7) risk. In the validation sample, the CIRA identified all individuals identified as vulnerable by national recommendations (having at least one risk factor). The category “elevated risk” maximised sensitivity (1) and specificity (0.97). The CIRA had even higher capacity in discriminating individuals vulnerable according to clinical evaluation (a four-level risk categorisation based on a consensus of medical staff). The category “elevated risk” maximised sensitivity and specificity (both 1). When considering the individuals classified as extremely high risk by medical staff, the category “high risk” had a high discriminatory capacity (sensitivity =0.89, specificity =0.97).
CONCLUSIONS: The CIRA scores have a high discriminative ability and will be important in custodial settings to support decisions and prioritise actions using a standardised valid assessment method. However, as knowledge on risk factors for COVID-19 mortality is still limited, the CIRA may be considered preliminary. Underlying data will be updated regularly on the website (http://www.prison-research.com), where the CIRA algorithm is freely available.
DESIGN: Cross-sectional study with a representative sample (development) and a case-control sample (validation).
SETTING: The two largest Swiss prisons.
PARTICIPANTS: (1) Development sample: all male persons detained in Pöschwies, Zurich (n = 365); (2) Validation sample: case-control sample of male persons detained in Champ-Dollon, Geneva (n = 192, matching 1:3 for participants at risk for severe course of COVID-19 and participants without risk factors).
MAIN OUTCOME MEASURES: The CIRA combined seven risk factors identified by the World Health Organization and the Swiss Federal Office of Public Health as predictive of severe COVID-19 to derive an absolute risk increase in mortality rate: Age ≥60 years, cardiovascular disease, diabetes, hypertension, chronic respiratory disease, immunodeficiency and cancer.
RESULTS: Based on the development sample, we proposed a three-level classification: average (<3.7), elevated (3.7-5.7) and high (>5.7) risk. In the validation sample, the CIRA identified all individuals identified as vulnerable by national recommendations (having at least one risk factor). The category “elevated risk” maximised sensitivity (1) and specificity (0.97). The CIRA had even higher capacity in discriminating individuals vulnerable according to clinical evaluation (a four-level risk categorisation based on a consensus of medical staff). The category “elevated risk” maximised sensitivity and specificity (both 1). When considering the individuals classified as extremely high risk by medical staff, the category “high risk” had a high discriminatory capacity (sensitivity =0.89, specificity =0.97).
CONCLUSIONS: The CIRA scores have a high discriminative ability and will be important in custodial settings to support decisions and prioritise actions using a standardised valid assessment method. However, as knowledge on risk factors for COVID-19 mortality is still limited, the CIRA may be considered preliminary. Underlying data will be updated regularly on the website (http://www.prison-research.com), where the CIRA algorithm is freely available.