Extended Postoperative Analgesia via Caudal Catheters for Major Surgery in Neonates-A 6-Year Retrospective Study.
Аннотация
Background
Caudal anesthesia is an important regional anesthetic technique in neonates. The placement of a catheter can provide excellent analgesia for a prolonged period; the role of adjuvants, in particular morphine, however, remains unclear. We aimed to describe our experience with caudal catheters for major surgery in neonates.
Methods
We included all neonates who had a caudal catheter placed for major abdominal and thoracic surgery and explored postoperative pain management and catheter complications. This retrospective case series included neonates with caudal catheter placement from October 2012 to April 2018 at a tertiary university hospital.
Results
A total of 33 caudal catheter placements in 32 neonates were included in this study, of which 28 (85%) were a laparotomy and 5 (15%) a thoracotomy. The mean catheter duration was 135 h with a postoperative failure rate of 3%. Patients who did not receive intravenous opioids postoperatively had a significantly shorter stay in the intensive care unit than those who did (341 h vs. 674 h, p = 0.01). All patients received continuous local anesthetics over the catheter, and 79% received additional intermittent epidural morphine postoperatively for a median period of 42 h. No infectious complications were reported.
Conclusions
Caudal catheters are a valuable option for perioperative analgesia for major surgery in neonates. We found no serious catheter-related complication. Further research is needed to define the optimal approach and combination of different analgesic techniques.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.