MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41551-022-00850-0

Медицинская библиотека · Nature biomedical engineering · 2022

Field validation of the performance of paper-based tests for the detection of the Zika and chikungunya viruses in serum samples.

Karlikow Margot, da Silva Severino Jefferson Ribeiro, Guo Yuxiu, Cicek Seray, Krokovsky Larissa, Homme Paige, Xiong Yilin, Xu Talia, Calderón-Peláez Maria-Angelica, Camacho-Ortega Sigrid, Ma Duo, de Magalhães Jurandy Júnior Ferraz, Souza Bárbara Nayane Rosário Fernandes, de Albuquerque Cabral Diego Guerra, Jaenes Katariina, Sutyrina Polina, Ferrante Tom, Benitez Andrea Denisse, Nipaz Victoria, Ponce Patricio, Rackus Darius G, Collins James J, Paiva Marcelo, Castellanos Jaime E, Cevallos Varsovia, Green Alexander A, Ayres Constância, Pena Lindomar, Pardee Keith

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПоддержка правительства СШАПеревод в очереди

Аннотация

In low-resource settings, resilience to infectious disease outbreaks can be hindered by limited access to diagnostic tests. Here we report the results of double-blinded studies of the performance of paper-based diagnostic tests for the Zika and chikungunya viruses in a field setting in Latin America. The tests involved a cell-free expression system relying on isothermal amplification and toehold-switch reactions, a purpose-built portable reader and onboard software for computer vision-enabled image analysis. In patients suspected of infection, the accuracies and sensitivities of the tests for the Zika and chikungunya viruses were, respectively, 98.5% (95% confidence interval, 96.2-99.6%, 268 serum samples) and 98.5% (95% confidence interval, 91.7-100%, 65 serum samples) and approximately 2 aM and 5 fM (both concentrations are within clinically relevant ranges). The analytical specificities and sensitivities of the tests for cultured samples of the viruses were equivalent to those of the real-time quantitative PCR. Cell-free synthetic biology tools and companion hardware can provide de-centralized, high-capacity and low-cost diagnostics for use in low-resource settings.

Для цитирования: Karlikow Margot, da Silva Severino Jefferson Ribeiro, Guo Yuxiu, Cicek Seray, Krokovsky Larissa, Homme Paige, Xiong Yilin, Xu Talia, Calderón-Peláez Maria-Angelica, Camacho-Ortega Sigrid, Ma Duo, de Magalhães Jurandy Júnior Ferraz, Souza Bárbara Nayane Rosário Fernandes, de Albuquerque Cabral Diego Guerra, Jaenes Katariina, Sutyrina Polina, Ferrante Tom, Benitez Andrea Denisse, Nipaz Victoria, Ponce Patricio, Rackus Darius G, Collins James J, Paiva Marcelo, Castellanos Jaime E, Cevallos Varsovia, Green Alexander A, Ayres Constância, Pena Lindomar, Pardee Keith. Field validation of the performance of paper-based tests for the detection of the Zika and chikungunya viruses in serum samples.. Nature biomedical engineering. 2022. DOI: 10.1038/s41551-022-00850-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.