DOI 10.1001/archinte.1994.00420230043006
A rapid test for infectious and inflammatory enteritis.
Аннотация
BACKGROUND
Inflammatory illnesses are an indication for specific diagnostic studies and possible antimicrobial therapy. The presence of fecal leukocytes has been used as a marker of inflammatory diarrhea; however, microscopic examination of the fecal smear is unreliable if the specimen is transported, refrigerated, frozen, or collected by swab.
OBJECTIVE
To evaluate a rapid, sensitive, semiquantitative test for detection of fecal leukocytes using antilactoferrin latex bead agglutination (LFLA), a test that remains sensitive even after specimens are refrigerated, frozen, or stored on swabs.
METHODS
LFLA titers were determined in stool specimens from previously healthy volunteers before and after experimental infection with different enteric pathogens and from patients with nosocomial diarrhea caused by Clostridium difficile.
RESULTS
Healthy controls and subjects with noninflammatory diarrhea caused by Vibrio cholerae consistently demonstrated LFLA titers less than 1:50. In contrast, subjects with inflammatory diarrhea caused by Shigella species and C difficile had markedly elevated titers. Titers for subjects with experimental shigellosis ranged from 1:50 to 1:3200, with seven (78%) of nine at 1:400 or greater. Titers for patients with C difficile enteritis ranged as high as 1:1200, with six (50%) of 12 at 1:400 or greater. Subjects with experimental enteropathogenic Escherichia coli infection also had elevated titers, ranging from 1:100 to 1:1600, with three (43%) of seven at 1:400 or greater. Titers for subjects with experimental enterotoxigenic E coli infection were moderately elevated, with nine (53%) of 17 ranging from 1:50 to 1:200 (only one [6%] of 17 was > or = 1:400), suggesting a mild inflammatory process.
CONCLUSIONS
The fecal LFLA assay distinguishes inflammatory from noninflammatory diarrhea, may provide new information on mildly inflammatory processes, and may be a useful, rapid test in a diagnostic algorithm for acute, infectious diarrheal illnesses.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.