m+Medelevator.RU
← Поиск публикаций
Forensic science international · 2004

A rapid screening procedure for drugs and poisons in gastric contents by direct injection-HPLC analysis.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Politi Lucia, Groppi Angelo, Polettini Aldo, Montagna Maria

Аннотация

A high performance liquid chromatographic method for toxicological drug screening of gastric content has been developed. The samples were diluted (1:3-1:30) in 0.01 N hydrochloric acid and injected into a reverse phase column for separation by gradient elution. Mobile phase consisted of solvent A (acetonitrile/water 90:10, 0.01 M sodium dodecylsulphate, 0.5% v/v glacial acetic acid) and solvent B (water/acetonitrile 90:10, 0.01 M sodium dodecylsulphate, 0.5% v/v glacial acetic acid); the gradient was programmed from 20 to 80% A in 30 min. The flow was kept constant at 1.5 ml/min. Two home-made internal standards, butyrylsalicylic acid and diacetyltubocurarine with retention times of 5.6 and 21.4 min, respectively, were used. Drugs are identified by matching their relative retention times and UV spectra (200-400 nm) with those contained in a home made library of more than 340 reference compounds (9 analgesics, 22 antidepressants, 30 antihistamines, 14 antihypertensives, 21 antirheumatics, 15 beta-blockers, 9 bronchodilators, 10 Ca antagonists, 14 diuretics, 26 neuroleptics, 25 tranquilizers, and other significant xenobiotic compounds). The fluorometric (FLD) emission spectrum (280-700 nm; excitation wavelength, 230 nm) was used as a further identification. At 50mg/l analyte concentrations, the injection of gastric content after dilution (1:3) produced S/N ratios in the range 8-140. The method is simple, rapid, rather inexpensive and proved to be a useful means of investigation if used in combination with GC-MS screening in blood. On the other hand, the system suffers from a relatively limited sensitivity for compounds with a low UV absorption and from interferences due to the presence in the matrix of some highly UV- and FL-responsive compounds (e.g. tryptophan).

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты