MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.bios.2012.05.031

Медицинская библиотека · Biosensors & bioelectronics · 2012

Electrochemical based detection of microRNA, mir21 in breast cancer cells.

Kilic Tugba, Topkaya Seda Nur, Ozkan Ariksoysal Dilsat, Ozsoz Mehmet, Ballar Petek, Erac Yasemin, Gozen Oguz

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

In this work, a novel electrochemical microRNA (miRNA) detection method based on enzyme amplified biosensing of mir21 from cell lysate of total RNA was demonstrated. The proposed enzymatic detection method was detailed and compared with the conventional guanine oxidation based assay in terms of detection limit and specificity. For the detection of mir21, capture probes and/or cell lysates were covalently attached onto the pencil graphite electrode (PGE) by coupling agents of N-(dimethylamino)propyl-N'-ethylcarbodiimide hydrochloride (EDC) and N-hydroxysulfosuccinimide (NHS). Having immobilized the capture probe onto the surface of PGE, hybridization was achieved with a biotinylated (from its 3' end) complementary target. Extravidin labeled alkaline phosphatase (Ex-Ap) binds to the biotinylated target due to the interaction between biotin-avidin and the enzyme converts electro-inactive alpha naphtyl phosphate (the substrate) to electro-active alpha naphtol (α-NAP, the product). α-NAP was oxidized at +0.23 V vs Ag/AgCl and this signal was measured by Differential Pulse Voltammetry (DPV). The signals obtained from α-NAP oxidation were compared for the probe and hybrid DNA. The specificity of the designed biosensor was proved by using non-complementary sequences instead of complementary sequences and the detection limit of the assay was calculated to be 6 pmol for cell lysates.

Для цитирования: Kilic Tugba, Topkaya Seda Nur, Ozkan Ariksoysal Dilsat, Ozsoz Mehmet, Ballar Petek, Erac Yasemin, Gozen Oguz. Electrochemical based detection of microRNA, mir21 in breast cancer cells.. Biosensors & bioelectronics. 2012. DOI: 10.1016/j.bios.2012.05.031.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.