Cytometry. Part A : the journal of the International Society for Analytical Cytology · 2011
In vivo flow cytometry of circulating clots using negative photothermal and photoacoustic contrasts.
СтатьяПоддержка NIH: внешняя программаПоддержка правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Galanzha Ekaterina I, Sarimollaoglu Mustafa, Nedosekin Dmitry A, Keyrouz Salah G, Mehta Jawahar L, Zharov Vladimir P
Аннотация
Conventional photothermal (PT) and photoacousic (PA) imaging, spectroscopy, and cytometry are preferentially based on positive PT/PA effects, when signals are above background. Here, we introduce PT/PA technique based on detection of negative signals below background. Among various new applications, we propose label-free in vivo flow cytometry of circulating clots. No method has been developed for the early detection of clots of different compositions as a source of thromboembolism including ischemia at strokes and myocardial infarction. When a low-absorbing, platelet-rich clot passes a laser-irradiated vessel volume, a transient decrease in local absorption results in an ultrasharp negative PA hole in blood background. Using this phenomenon alone or in combination with positive contrasts, we demonstrated identification of white, red, and mixed clots on a mouse model of myocardial infarction and human blood. The concentration and size of clots were measured with threshold down to few clots in the entire circulation with size as low as 20 μm. This multiparameter diagnostic platform using portable personal high-speed flow cytometer with negative dynamic contrast mode has potential to real-time defining risk factors for cardiovascular diseases, and for prognosis and prevention of stroke or use clot count as a marker of therapy efficacy. Possibility for label-free detection of platelets, leukocytes, tumor cells or targeting themby negative PA probes (e.g., nonabsorbing beads or bubbles) is also highlighted.
Предметные рубрики MeSH
AnimalsBlood CoagulationBlood PlateletsCarotid ArteriesDisease Models, AnimalEarly DiagnosisFlow CytometryFluoresceinsFluorescent DyesHumansMesenteryMiceMice, NudeMolecular ImagingMyocardial InfarctionPhotoacoustic TechniquesPlatelet AggregationRatsRats, Sprague-DawleySplanchnic CirculationStrokeSuccinimidesThromboembolism