MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.ppat.1010039

Медицинская библиотека · PLoS pathogens · 2021

Species-specific quantification of circulating ebolavirus burden using VP40-derived peptide variants.

Shu Qingbo, Kenny Tara, Fan Jia, Lyon Christopher J, Cazares Lisa H, Hu Tony Y

СтатьяПоддержка NIH: внешняя программаПоддержка правительства СШАПеревод в очереди

Аннотация

Six ebolavirus species are reported to date, including human pathogens Bundibugyo virus (BDBV), Ebola virus (EBOV), Sudan virus (SUDV), and Taï Forest virus (TAFV); non-human pathogen Reston virus (RESTV); and the plausible Bombali virus (BOMV). Since there are differences in the disease severity caused by different species, species identification and viral burden quantification are critical for treating infected patients timely and effectively. Here we developed an immunoprecipitation-coupled mass spectrometry (IP-MS) assay for VP40 antigen detection and quantification. We carefully selected two regions of VP40, designated as peptide 8 and peptide12 from the protein sequence that showed minor variations among Ebolavirus species through MS analysis of tryptic peptides and antigenicity prediction based on available bioinformatic tools, and generated high-quality capture antibodies pan-specific for these variant peptides. We applied this assay to human plasma spiked with recombinant VP40 protein from EBOV, SUDV, and BDBV and virus-like particles (VLP), as well as EBOV infected NHP plasma. Sequence substitutions between EBOV and SUDV, the two species with highest lethality, produced affinity variations of 2.6-fold for p8 and 19-fold for p12. The proposed IP-MS assay differentiates four of the six known EBV species in one assay, through a combination of p8 and p12 data. The IP-MS assay limit of detection (LOD) using multiple reaction monitoring (MRM) as signal readout was determined to be 28 ng/mL and 7 ng/mL for EBOV and SUDV respectively, equivalent to ~1.625-6.5×105 Geq/mL, and comparable to the LOD of lateral flow immunoassays currently used for Ebola surveillance. The two peptides of the IP-MS assay were also identified by their tandem MS spectra using a miniature MALDI-TOF MS instrument, greatly increasing the feasibility of high specificity assay in a decentralized laboratory.

Для цитирования: Shu Qingbo, Kenny Tara, Fan Jia, Lyon Christopher J, Cazares Lisa H, Hu Tony Y. Species-specific quantification of circulating ebolavirus burden using VP40-derived peptide variants.. PLoS pathogens. 2021. DOI: 10.1371/journal.ppat.1010039.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.