MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.dadr.2026.100451

Медицинская библиотека · Drug and alcohol dependence reports · 2026

Reference values for the alcohol biomarker phosphatidylethanol (PEth) in the Belgian population: Insights from a nationwide microsampling study.

Vandenbroucke Kevin, Van Uytfanghe Katleen, Heughebaert Liesl, Berger Nicolas, De Boosere Evy, Stove Christophe P

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Phosphatidylethanol 16:0/18:1 (PEth) is a well-established direct biomarker for monitoring recent and chronic alcohol consumption. However, population-based surveys assessing PEth in both people who drink alcohol and people who do not drink alcohol remain limited, despite their value for contextualizing forensic and clinical results.

METHODS

PEth was quantified in samples collected during the 2022-2023 Belgian National Food Consumption Survey (n = 487) using capillary volumetric absorptive microsampling (VAMS) and an ISO17025-accredited liquid chromatography-tandem mass spectrometry method (10-2000 ng/mL). Participants also completed an AUDIT-C questionnaire; relationships with PEth were evaluated using Spearman correlation and Cohen's kappa. Weighted data were used to derive estimates for the general Belgian population and compared with two presumed higher-consumption subgroups.

RESULTS

PEth concentrations in the general Belgian population ranged from <10 to 1400 ng/mL. Overall, 35.7% had concentrations between 20 and 200 ng/mL and 10.7% exceeded 200 ng/mL. PEth correlated strongly with AUDIT-C scores, with Spearman's rank correlation coefficients of 0.61 in males and 0.64 in females. Agreement between PEth and AUDIT-C for identifying hazardous drinking was moderate in males and substantial in females (Cohen's kappa: 0.55 and 0.63, respectively). The median PEth concentration in the general population was 17 ng/mL (95% CI: 15-18), compared with 32 ng/mL in a non-abstinent adult population and 122 ng/mL in individuals enrolled in a driver's license regranting program.

CONCLUSION

These findings provide population-based PEth reference data for Belgium and demonstrate clear differences in PEth distributions between general and higher-exposure populations, supporting improved contextual interpretation of forensic and clinical PEth results.

Для цитирования: Vandenbroucke Kevin, Van Uytfanghe Katleen, Heughebaert Liesl, Berger Nicolas, De Boosere Evy, Stove Christophe P. Reference values for the alcohol biomarker phosphatidylethanol (PEth) in the Belgian population: Insights from a nationwide microsampling study.. Drug and alcohol dependence reports. 2026. DOI: 10.1016/j.dadr.2026.100451.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.