Accuracy of Valproic Acid Concentration Correction Based on Serum Albumin.

Drisaldi Aulbrey, Weeda Erin, Neyens Ron, Orvin Nicholas, Bonilha Leonardo, Campbell Zeke, Bohm Nicole

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Patient-specific factors can alter the pharmacokinetic disposition of valproic acid. Specifically, the free fraction of valproic acid can increase substantially in patients with hypoalbuminemia or as serum drug concentrations rise due to saturable protein binding. Direct measurement of free serum drug concentrations allows for accurate assessment of drug levels, but the assay may not be readily available in all institutions. The effect of hypoalbuminemia on free fraction has been quantified and serves as the basis of an equation used to "correct" measured total valproic acid concentrations. The aim of this study was to evaluate the accuracy of the equation.

METHODS

This retrospective study included adult patients with measurable free and total valproic acid concentrations between July 2014 and June 2017. The primary aim was to assess the relationship between measured and predicted free valproic acid concentrations. Free levels were categorized as subtherapeutic, therapeutic, or supratherapeutic based on the reference range of 7-23 mg/L. Concordance was defined as measured and predicted concentrations falling within the same category.

RESULTS

The analysis included 174 patients with a median age of 58 years and a median albumin of 3 g/dL. The majority of patients were hospitalized (88.5%). Concordance occurred in 56.9% of samples. A Spearman's correlation coefficient of 0.60 (p < 0.001) was found between the measured and predicted free valproic acid concentrations. Concordance of concentrations was 42% for ICU patients, 63% for floor patients, and 65% for outpatients. Of those with discordant concentrations, 97% of the predicted concentrations underestimated the measured concentrations.

CONCLUSIONS

There is discordance between predicted and measured free serum valproic acid concentrations when using the proposed equation. Because of the potential impact of underestimation and variability of free valproic acid concentrations, a measured free level is the ideal option for therapeutic drug monitoring of valproic acid.

Для цитирования: Drisaldi Aulbrey, Weeda Erin, Neyens Ron, Orvin Nicholas, Bonilha Leonardo, Campbell Zeke, Bohm Nicole. Accuracy of Valproic Acid Concentration Correction Based on Serum Albumin.. Neurocritical care. 2019. DOI: 10.1007/s12028-018-0627-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.