Liquid chromatography-tandem mass spectrometry method for simultaneous determination of valproic acid and its ene-metabolites in epilepsy patient plasma.

Lu Huan, Su Chong, Yin Lei, Gu Liqiang, Gu Jingkai, Chen Xiaohui

СтатьяПеревод в очереди

Аннотация

A simple and high throughput method was developed and validated for simultaneous determination of valproic acid and its two toxicant ene-metabolites, 2-enevalproic acid and 4-enevalproic acid in epilepsy patient plasma using liquid chromatography-tandem mass spectrometry. Probenecid was used as internal standard and solid-phase extraction was selected for sample preparation. A chromatographic separation was performed on an Agilent Poroshell SB-C18 column (50 mm×4.6 mm i.d., 2.7 μm) by an optimized gradient elution at a flow rate of 0.9 mL/min. The total run time was 7 min. Electrospray ionization was used in negative ion mode by multiple reaction monitoring of the precursor-to-product ion transitions at m/z 143.0→143.0 for valproic acid, m/z 140.9→140.9 for 2-enevalproic acid and 4-enevalproic acid for their poor fragments, and m/z 283.9→239.9 for probenecid. The results showed good linearity of valproic acid, 2-enevalproic acid and 4-enevalproic acid in their respective linear ranges. The correlation coefficients were more than 0.998. The intra- and inter-day precision of the assay was less than 11.0% and the accuracy ranged from 2% to 12%. This analytical method was successfully applied to assay plasma concentrations of valproic acid and its two ene-metabolites in epilepsy patient plasma and used for therapeutic drug monitoring.

Для цитирования: Lu Huan, Su Chong, Yin Lei, Gu Liqiang, Gu Jingkai, Chen Xiaohui. Liquid chromatography-tandem mass spectrometry method for simultaneous determination of valproic acid and its ene-metabolites in epilepsy patient plasma.. Journal of pharmaceutical analysis. 2015. DOI: 10.1016/j.jpha.2015.11.006.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.