MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.drugalcdep.2025.112559

Медицинская библиотека · Drug and alcohol dependence · 2025

Validation of screening instruments for alcohol and substance use disorders among men and women in Eastern Cape, South Africa.

Stockton Melissa A, Mazinyo Ernesha Webb, Mlanjeni Lungelwa, Ngcelwane Nondumiso, Nogemane Kwanda, Nobatyi Phumza, Sweetland Annika C, Basaraba Cale, Greene M Claire, Bezuidenhout Charl, Grobler Christoffel, Wall Melanie M, Medina-Marino Andrew, Wainberg Milton L

СтатьяВалидационное исследованиеПеревод в очереди

Аннотация

INTRODUCTION

Valid Alcohol Use Disorder (AUD) and Substance Use Disorder (SUD) screeners are needed to identify and link people to services. We evaluated the performance of several AUD and SUD screeners in South Africa using the Mini International Neuropsychiatric Interview (MINI)-5 diagnostic gold standard.

METHODS

Adults at primary and tertiary care facilities in Buffalo City Metro, South Africa, were screened by research assistants using the AUDIT and AUDIT-C (AUD), DAST-10 (SUD) and NIDA Quick Screen (AUD and SUD). Nurses administered the MINI-5 to identify AUD and SUD. We assessed the internal consistency, criterion validity, sensitivity and specificity of these tools, stratified by gender.

RESULTS

Among 1885 participants, the prevalence of AUD and SUD were 9.5 % and 1.6 %, respectively. All tools demonstrated adequate internal consistency and criterion validity. A positive AUDIT screen (men: ≥8; women: ≥7) yielded sensitivity/specificity of 70.6/87.3 % (men: 78.7/82.6 %; women: 64.8/89.8 %). A positive AUDIT-C screen (men: ≥4; women: ≥3) yielded sensitivity/specificity of 66.1/82.0 % (men: 64.0/78.8 %; women: 67.6/81.3 %). Endorsing the NIDA alcohol use question yielded sensitivity/specificity of 71.1/68.1 % (men: 74.7/59.7 %; women: 68.6/72.5 %). Endorsing either NIDA substance use questions yielded sensitivity/specificity of 80.6/91.7 % (men: 80.8/89.0 %; women: 80.0/93.1 %). A DAST-10 cut-off of ≥ 3 yielded sensitivity/specificity of 71.0/96.0 % (men: 73.1/83.7 %; women 60.0/97.4 %).

CONCLUSIONS

The AUDIT and AUDIT-C performed similarly among men and women, although lower cut-offs may optimize performance among women. The low number of SUD cases hampered our ability to draw conclusions about the SUD screeners' performance.

Для цитирования: Stockton Melissa A, Mazinyo Ernesha Webb, Mlanjeni Lungelwa, Ngcelwane Nondumiso, Nogemane Kwanda, Nobatyi Phumza, Sweetland Annika C, Basaraba Cale, Greene M Claire, Bezuidenhout Charl, Grobler Christoffel, Wall Melanie M, Medina-Marino Andrew, Wainberg Milton L. Validation of screening instruments for alcohol and substance use disorders among men and women in Eastern Cape, South Africa.. Drug and alcohol dependence. 2025. DOI: 10.1016/j.drugalcdep.2025.112559.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.