MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jpedsurg.2012.09.047

Медицинская библиотека · Journal of pediatric surgery · 2013

Central venous cutdown in neonates: feasibility as a bedside procedure without general anesthesia.

Hong Sung-Min, Lee Hyeon-Soo, Moon Suk-Bae

СтатьяПеревод в очереди

Аннотация

BACKGROUND/PURPOSE: A silicone central venous catheter (CVC) is usually inserted using a percutaneous technique under general anesthesia. However, there are numerous reports on the postoperative adverse effects of general anesthesia in neonates. The aim of this study is to investigate the feasibility of open surgical cutdown (OSC) for central venous access without general anesthesia.

METHODS

The medical records of patients who underwent OSC at bedside under sedation and local anesthesia were reviewed. Chloral hydrate (100mg/kg) was given orally for the induction of moderate to deep sedation 15 minutes before OSC; then the operative field was infiltrated with 1% lidocaine. When adequate sedation was not achieved, a bolus of phenobarbital (20mg/kg) was given intravenously.

RESULTS

Thirteen Broviac lines were inserted into 12 patients. At insertion, the median gestational age was 29 weeks, birth weight was 1,140 g and age was 33 days. No patients required invasive ventilator care; 7 patients received nasal non-invasive ventilator care. Neither intubation nor inotropics were required during the intra- or postoperative period and no perioperative surgical complications occurred. The median catheter duration was 19.5 days.

CONCLUSION

OSC at bedside for CVC insertion, using adequate sedation and local anesthesia, is a feasible procedure in neonates.

Для цитирования: Hong Sung-Min, Lee Hyeon-Soo, Moon Suk-Bae. Central venous cutdown in neonates: feasibility as a bedside procedure without general anesthesia.. Journal of pediatric surgery. 2013. DOI: 10.1016/j.jpedsurg.2012.09.047.