MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Saudi medical journal · 2007

Rapid sequence induction and intubation with 1 mg/kg rocuronium bromide in cesarean section, comparison with suxamethonium.

Abu-Halaweh Sami A, Massad Islam M, Abu-Ali Hamdi M, Badran Izdiad Z, Barazangi Bassam A, Ramsay Michael A

СтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

To demonstrate that Rocuronium Bromide can be used for rapid sequence induction in emergency conditions.

METHODS

Our study was performed between December 2005 and May 2006 in Jordan University Hospital, Jordan. We studied the efficacy and intubating conditions after administrating of Rocuronium Bromide 1 mg/kg at 60 second in group of 60 pregnant women undergoing elective or emergency cesarean section and compared the results with those obtained after giving Suxamethonium 1 mg/kg at 60 seconds in a group of patients similar to the Rocuronium group.

RESULTS

Intubating conditions after 1 mg /kg of Rocuronium Bromide were found to be acceptable (good and excellent) in 95% of patients and were similar to the Suxamethonium group (97%). The endotracheal tube could be passed through the vocal cards of all patients enrolled in the study.

CONCLUSION

Rocuronium Bromide 1 mg/kg can be safely used for rapid sequence induction in cesarean section and the intubating conditions are similar to those of Suxamethonium.

Для цитирования: Abu-Halaweh Sami A, Massad Islam M, Abu-Ali Hamdi M, Badran Izdiad Z, Barazangi Bassam A, Ramsay Michael A. Rapid sequence induction and intubation with 1 mg/kg rocuronium bromide in cesarean section, comparison with suxamethonium.. Saudi medical journal. 2007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.