MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/rcm.9732

Медицинская библиотека · Rapid communications in mass spectrometry : RCM · 2024

Study of the impurity profile of photodegradation in lomefloxacin hydrochloride ear drops using liquid chromatography combined with ion trap/time-of-flight mass spectrometry.

Zeng Hongxia, Yang Ying, Gao Jiarui, Zhou Yuping, Zheng Jinqi

СтатьяПеревод в очереди

Аннотация

RATIONALE: Lomefloxacin hydrochloride ear drops are highly unstable to light and prone to produce photodegradation impurities. These impurities might be related to the phototoxicity of lomefloxacin, which could seriously threaten the health of patients. In this article, the photodegradation impurity profile in lomefloxacin hydrochloride ear drops was studied for further improvement of quality control of the drug.

METHODS

By studying the chromatographic behavior of photodegradation impurities, the photodegradation impurities in lomefloxacin hydrochloride ear drops were separated and detected effectively. Liquid chromatography combined with ion trap/time-of-flight mass spectrometry was applied to characterize the structures of the photodegradation impurities in lomefloxacin hydrochloride ear drops.

RESULTS

The structures of 17 impurities in lomefloxacin hydrochloride ear drops were elucidated based on high-resolution MSn data in positive ion mode, 12 of them being unknown impurities.

CONCLUSIONS

The structural characteristics and fragmentation patterns of the photodegradation impurities were also studied. The study of the photodegradation impurity profile in lomefloxacin hydrochloride ear drops provides a scientific basis for quality control of these ear drops and ensures the safety of drug use by the public.

Для цитирования: Zeng Hongxia, Yang Ying, Gao Jiarui, Zhou Yuping, Zheng Jinqi. Study of the impurity profile of photodegradation in lomefloxacin hydrochloride ear drops using liquid chromatography combined with ion trap/time-of-flight mass spectrometry.. Rapid communications in mass spectrometry : RCM. 2024. DOI: 10.1002/rcm.9732.