Development and evaluation of an anatomically designed and 3D printed device to enhance orotracheal intubation success in rabbits by inexperienced veterinarians.

Nejamkin Pablo, Clausse María, Landivar Florencia, Lorenzutti Matías A, Cavilla Verónica, Viviani Paula, Alvarez Luis I, Del Sole María J

Randomized Controlled Trial, VeterinaryСтатьяПеревод в очереди

Аннотация

OBJECTIVE

To assess whether the use of a three-dimensional (3D) printed device enhances the success rate of orotracheal intubation in rabbits.

STUDY

DESIGN

Prospective, crossover randomized controlled trial.

ANIMALS: A total of six mixed-breed rabbits.

METHODS

A device to guide the endotracheal tube was designed based on computed tomography images and then manufactured using 3D printing. Rabbits were randomly assigned for intubation by two inexperienced veterinarians using the blind (BLI), borescope- (BOR) or device- (DEV) guided techniques. Success rate, number of attempts, time to success, injury scores and propofol dose were recorded and compared. Significance was considered when p < 0.05.

RESULTS

Success rate was higher in DEV (58.3%) than in BLI (8.3%) (p < 0.023), but not different from that in BOR (41.6%). Total time until successful intubation was lower in DEV (45 ± 23 seconds) and BOR (85 ± 62 seconds) than in BLI (290 seconds; p < 0.006). Time for the successful attempt was lower for DEV (35 ± 10 seconds) and BOR (74 ± 43 seconds) than in BLI (290 seconds; p < 0.0001). The propofol dose required was lower for DEV (2.3 ± 1.2 mg kg-1) than for BLI (3.4 ± 1.6 mg kg-1) (p < 0.031), but not different from BOR (2.4 ± 0.9 mg kg-1). Number of attempts and oxygen desaturation events were not different among techniques (p < 0.051 and p < 0.326, respectively). Injury scores [median (range)] before and after attempts were different in BLI [0 versus 1 (0-3), p < 0.005] and BOR [0 (0-1) versus 1 (0-3), p < 0.002] but not in DEV [0 (0-2) versus 0 (0-3), p < 0.109].

CONCLUSIONS AND CLINICAL RELEVANCE: The device facilitated orotracheal intubation with a time similar to the borescope-guided technique but faster than the traditional blind technique.

Для цитирования: Nejamkin Pablo, Clausse María, Landivar Florencia, Lorenzutti Matías A, Cavilla Verónica, Viviani Paula, Alvarez Luis I, Del Sole María J. Development and evaluation of an anatomically designed and 3D printed device to enhance orotracheal intubation success in rabbits by inexperienced veterinarians.. Veterinary anaesthesia and analgesia. 2023. DOI: 10.1016/j.vaa.2023.03.001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.