MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jchromb.2017.12.006

Медицинская библиотека · Journal of chromatography. B, Analytical technologies in the biomedical and life sciences · 2017

An improved liquid chromatography tandem mass spectrometry (LC-MS/MS) method for quantification of dexmedetomidine concentrations in samples of human plasma.

Moosavi Seyed Mojtaba, Shekar Kiran, Fraser John F, Smith Maree T, Ghassabian Sussan

СтатьяПеревод в очереди

Аннотация

Dexmedetomidine (DMET) is a sedative, analgesic and anxiolytic with minimum adverse respiratory effects. An LC-MS/MS bioanalytical method has been developed and validated to accurately measure DMET concentrations in samples of human plasma. The method overcomes difficulties in the extraction and quantification of DMET due to the fact that it binds strongly to glass and plastic tubes, as well as solid phase extraction (SPE) cartridges. Human plasma (50 μL) was mixed with the internal standard (IS) (DMET-d4) solution (100 μL) and 0.1% formic acid (50 μL) and extracted using Oasis HLB 1 CC (30 mg) solid phase extraction (SPE) cartridges (Waters®). The glass tubes were coated with bovine serum albumin (BSA) 0.5% (20 μL) before eluting DMET and the IS. After evaporation under nitrogen at room temperature, the analytes were reconstituted in 20% acetonitrile in 0.1% formic acid in water and transferred to silanized glass vials. An electrospray ionisation (ESI) mass spectrometry method in positive mode was created and the precursor/product transitions (m/z) were 201.1 → 95.0 (DMET) and 204.9 → 99.0 (IS). The method was robust and fully validated based on the 2012 EMEA guideline for bioanalytical method validation in the concentration range of 0.5-20 ng/mL. Using this assay, we showed that DMET binds strongly to Extracorporeal Membrane Oxygenation (ECMO) circuits, consistent with expectations for small lipophilic compounds.

Для цитирования: Moosavi Seyed Mojtaba, Shekar Kiran, Fraser John F, Smith Maree T, Ghassabian Sussan. An improved liquid chromatography tandem mass spectrometry (LC-MS/MS) method for quantification of dexmedetomidine concentrations in samples of human plasma.. Journal of chromatography. B, Analytical technologies in the biomedical and life sciences. 2017. DOI: 10.1016/j.jchromb.2017.12.006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.