Intravenous lidocaine infusion reduces bispectral index-guided requirements of propofol only during surgical stimulation.
Аннотация
BACKGROUND
I.V. lidocaine reduces volatile anaesthetics requirements during surgery. We hypothesized that lidocaine would also reduce propofol requirements during i.v. anaesthesia.
METHODS
A randomized controlled study of 40 patients tested the effect of i.v. lidocaine (1.5 mg kg(-1) then 2 mg kg(-1) h(-1)) on propofol requirements. Anaesthesia was maintained with remifentanil and propofol target-controlled infusions (TCI) to keep the bispectral index (BIS) around 50. Effect-site concentrations of propofol and remifentanil and BIS values were recorded before and after skin incision. Data were analysed using anova and mixed effects analysis with NONMEM. Two dose-response studies were then performed with and without surgical stimulation. Propofol TCI titrated to obtain a BIS around 50 was kept constant. Then patients were randomized into four groups: A, saline; B, 0.75 mg kg(-1) bolus then infusion 1 mg kg(-1) h(-1); C, 1.5 mg kg(-1) bolus and infusion 2 mg kg(-1) h(-1); and D, 3 mg kg(-1) bolus and infusion 4 mg kg(-1) h(-1). Lidocaine administration coincided with skin incision. BIS values and haemodynamic variables were recorded. Data were analysed using linear regression and two-way anova.
RESULTS
Lidocaine decreased propofol requirements (P<0.05) only during surgery. In the absence of surgical stimulation, lidocaine did not affect BIS nor haemodynamic variables, whereas it reduced BIS increase (P=0.036) and haemodynamic response (P=0.006) secondary to surgery.
CONCLUSIONS
The sparing effect of lidocaine on anaesthetic requirements seems to be mediated by an anti-nociceptive action.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.