DOI 10.1111/j.1532-849x.2006.00064.x

Медицинская библиотека · Journal of prosthodontics : official journal of the American College of Prosthodontists · 2006

In vivo stress behavior in cemented and screw-retained five-unit implant FPDs.

Karl Matthias, Taylor Thomas D, Wichmann Manfred G, Heckmann Siegfried M

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: When fixing implant-supported fixed partial dentures (FPDs), it is important to achieve passive fit. The objective of the in vivo study presented was to quantify the strain development during the fixation of screw- and cement-retained FPDs.

MATERIALS AND

METHODS

After informed patient consent had been obtained (Ethics commission Approval No. 2315; FAU Erlangen-Nuremberg, Germany), four groups of five-unit FPDs (five samples per group) were fabricated and investigated in vivo. Group 1: Cementable, repositioning technique impression, burn out plastic coping; Group 2: Screwable, pickup technique impression, burn out plastic coping; Group 3: Screwable, pickup technique impression, cast to gold cylinder; Group 4: Screwable, pickup technique impression, bonded to gold cylinder. Two strain gauges (SG) were attached to the pontics of each bridge (SG-M and SG-D) to measure the strains that occurred during either the cementing or screw-in process. The final values were recorded for analysis.

RESULTS

The mean strain values (microm/m) for each SG were: Group 1: SG-M 32 microm/m, SG-D: 89 microm/m; Group 2: SG-M 302 microm/m, SG-D: 197 microm/m; Group 3: SG-M 458 microm/m, SG-D: 268 microm/m; Group 4: SG-M 269 microm/m, SG-D: 52 microm/m.

CONCLUSIONS

Although the bridges were clinically acceptable, none of them revealed a truly passive fit with zero microstrain. In contrast to conventional screw-retained bridges, cement retention seems to result in lower strain levels. Bonding bridge pontics to prefabricated implant components seems to allow both the retrievability of a screw-retained bridge and produce moderate strain values.

Для цитирования: Karl Matthias, Taylor Thomas D, Wichmann Manfred G, Heckmann Siegfried M. In vivo stress behavior in cemented and screw-retained five-unit implant FPDs.. Journal of prosthodontics : official journal of the American College of Prosthodontists. 2006. DOI: 10.1111/j.1532-849x.2006.00064.x.

Предметные рубрики MeSH