Comparison of midazolam, propofol and fentanyl combinations for sedation and hemodynamic parameters in cataract extraction.

Celiker Varol, Basgul Elif, Sahin Altan, Uzun Sennur, Bahadir Betul, Aypar Ulku

Сравнительное исследованиеСтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

Midazolam, propofol and fentanyl were compared in terms of sedation during cataract extraction. Hemodynamic parameters, sedation level, postoperative satisfaction, and side effects were investigated.

METHODS

The study was carried out in Hacettepe University Hospitals Ophthalmology Operating Theatres in 2005. The patients received only midazolam (0.02 mg kg-1), or midazolam (0.02 mg kg-1) + propofol (0.2 mg kg-1), or midazolam (0.02 mg kg-1) + fentanyl (1 microgram kg-1), or midazolam (0.02 mg kg-1) + propofol (0.2 mg kg-1) + fentanyl (1 microgram kg-1). The sedation level of patients was measured according to a physician questionnaire. Postoperative nausea/vomiting, headache, and patient satisfaction were determined via a patient's evaluation scale.

RESULTS

In the groups receiving fentanyl, the hemodynamic response to peribulbar block insertion was minimal (p<0.05) and the sedation level was best (p<0.05). Respiration rate and O2 saturation of patients receiving midazolam, propofol, and fentanyl decreased after sedation (p<0.01) and postoperative satisfaction was high in this group (p<0.01). Patients in the midazolam group showed a prominent reaction to peribulbar block insertion while movement during the operation was obvious (p<0.05).

CONCLUSION

The combination of midazolam, propofol, and fentanyl should be preferred to other study groups as the sedation level is suitable for cataract extraction with high postoperative patient satisfaction and without any side effects.

Для цитирования: Celiker Varol, Basgul Elif, Sahin Altan, Uzun Sennur, Bahadir Betul, Aypar Ulku. Comparison of midazolam, propofol and fentanyl combinations for sedation and hemodynamic parameters in cataract extraction.. Saudi medical journal. 2007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.