Propofol-based sedation does not negatively influence oxygenator running time compared to midazolam in patients with extracorporeal membrane oxygenation.
Аннотация
OBJECTIVE
Patients on extracorporeal membrane oxygenation are frequently in need for sedation. Use of propofol has been associated with impaired oxygenator function due to adsorption to the membrane as well as lipid load. The aim of our retrospective analysis was to compare two different sedation regimens containing either propofol or midazolam with respect to oxygenator running time.
METHODS
Midazolam was used in 73 patients whereas propofol was used in 49 patients, respectively. In the propofol group, veno-arterial-extracorporeal membrane oxygenation was used predominantly (84%), while veno-venous-extracorporeal membrane oxygenation was used more often in the midazolam group (64%).
RESULTS
Oxygenator running time until first exchange was 7 days in both groups ( p = 0.759). No statistically significant differences could be observed between the subgroup of patients receiving lipid-free (n = 24) and lipid-containing (n = 31) parenteral nutrition, respectively. Laboratory parameters like triglycerides, free hemoglobin, fibrinogen, platelets, and activated partial thromboplastin time were not significantly different between both sedation regimens ( p = 0.462, p = 0.489, p = 0.960, p = 0.134, and p = 0.843) and were not associated with oxygenator running time.
CONCLUSION
The use of propofol as sedative seems suitable in patients undergoing extracorporeal membrane oxygenation therapy.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.