DOI 10.1093/ehjdh/ztag075

Медицинская библиотека · European heart journal. Digital health · 2026

Artificial intelligence-based ECG as a triage tool for acute myocardial infarction: a diagnostic systematic review and meta-analysis.

Gaelzer Giulia Caldeira, Batista Pedro Gomes, Montenegro Marcela Vasconcelos, Dos Santos Silva Railla Raquel Albino, Malik Mushrin, Tebet Maria Leticia Carnielli, Fischer-Bacca Caroline O, Giorgi Juliana, Marques Gustavo Lenci

СтатьяОбзорПеревод в очереди

Аннотация

Early identification of acute myocardial infarction (AMI) remains challenging, particularly in non-ST-segment elevation presentations and occluded myocardial infarction, where conventional electrocardiogram (ECG) interpretation has limited sensitivity. Artificial intelligence-enabled ECG (AI-ECG) has emerged as a promising strategy to enhance early triage and diagnostic accuracy. To systematically evaluate the diagnostic performance of AI-enabled ECG algorithms for the detection of AMI, including ST-segment elevation myocardial infarction (STEMI) and non-ST-segment elevation myocardial infarction (NSTEMI), across diverse clinical settings. This diagnostic systematic review and meta-analysis was conducted in accordance with PRISMA guidelines and registered in PROSPERO (CRD420261292271). PubMed, Embase, and Cochrane CENTRAL were searched through January 2026. Studies evaluating AI-based ECG models for AMI detection and reporting sufficient data to reconstruct 2 × 2 contingency tables were included. Pooled sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were estimated using random-effects models (restricted maximum likelihood). Summary receiver operating characteristic (SROC) curves and area under the curve (AUC) were generated. Pre-specified subgroup analyses were performed for STEMI and NSTEMI Ten observational studies comprising 94 510 participants were included. For overall AMI detection,. AI-ECG demonstrated a pooled sensitivity of 89.4% (95% CI, 79.7-94.8) and specificity of 96% (95% CI, 91.2-98.2). The pooled NPV was 98.7% (95% CI, 94.1-99.7), and the pooled PPV was 73.3% (95% CI, 50.2-88.2). The SROC AUC was 0.97 (95% CI, 0.92-0.98). In STEMI, pooled sensitivity and specificity were 94.4% and 97.5%, respectively (AUC 0.98). In NSTEMI, pooled sensitivity was lower at 65.0%, with specificity of 87.5% and an AUC of 0.71. Heterogeneity was substantial, particularly among NSTEMI cohorts. AI-enabled ECG demonstrates high sensitivity and consistently excellent negative predictive value for AMI detection, supporting its role as a scalable, non-invasive triage adjunct at first medical contact. These findings highlight the potential of AI-ECG to facilitate early rule-out strategies and improve prioritization of patients requiring urgent ischaemic evaluation. Beyond diagnostic accuracy, AI-ECG may support probabilistic risk stratification and integration into early clinical decision-making pathways.

Для цитирования: Gaelzer Giulia Caldeira, Batista Pedro Gomes, Montenegro Marcela Vasconcelos, Dos Santos Silva Railla Raquel Albino, Malik Mushrin, Tebet Maria Leticia Carnielli, Fischer-Bacca Caroline O, Giorgi Juliana, Marques Gustavo Lenci. Artificial intelligence-based ECG as a triage tool for acute myocardial infarction: a diagnostic systematic review and meta-analysis.. European heart journal. Digital health. 2026. DOI: 10.1093/ehjdh/ztag075.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.