DOI 10.1213/ane.0b013e318203b7c0
Morphine distribution in the spinal cord after chronic infusion in pigs.
Аннотация
BACKGROUND
Continuous intrathecal drug delivery provides new options for chronic delivery of drugs that target the spinal cord, but therapeutic efficacy is highly variable. Using an acute porcine model, we have previously demonstrated that continuous intrathecal drug delivery efficacy may be highly variable because of severely limited drug distribution in the cerebrospinal fluid and spinal cord. We designed this study to determine whether the limited drug distribution observed in our acute studies occurs with chronic administration as well.
METHODS
Four farm-bred pigs were implanted with intrathecal infusion pumps delivering morphine (1 mg/mL) at 20 μL per hour. Because of a programming error, 1 additional pig received intrathecal morphine at 2 μL per hour. Drug infusion continued for 14 days, during which time animal activity was unrestricted. At the end of 2 weeks the animals were anesthetized and euthanized and their spinal cords removed. The spinal cords were divided into 1-cm sections and morphine concentrations measured.
RESULTS
As with previous acute animal studies, drug distribution was extremely limited. Morphine concentration decreased exponentially as a function of distance from the catheter tip, resulting in a 5- to 10-fold decrease over a distance of only 5 to 10 cm.
CONCLUSION
Morphine distribution is very limited during chronic intrathecal delivery in ambulatory pigs, and there are significant spinal cord drug concentration gradients as a function of distance from the infusion point. Consequently, catheter tip position may be critical, particularly when infusing isobaric solutions. These data also support the hypothesis that inflammatory masses complicating chronic intrathecal opioid delivery occur at the catheter tip because limited drug distribution results in extremely high drug concentrations at that point.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.