Potentiation by ketamine of fentanyl antinociception. I. An experimental study in rats showing that ketamine administered by non-spinal routes targets spinal cord antinociceptive systems.

Nadeson R, Tucker A, Bajunaki E, Goodchild C S

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Ketamine has been found to exert antinociceptive effects in animals and to be analgesic at subanaesthetic doses in humans. This study was designed to investigate the involvement of spinal cord mechanisms in the potentiation of opioid analgesia by parenteral non-spinal administration of ketamine.

METHODS

Thresholds for nociception were measured in an acute pain model in rats that allowed identification of antinociceptive effects due to drug action in the spinal cord. Dose-response curves for the antinociceptive effects of ketamine alone and ketamine in conjunction with the mu opioid fentanyl were constructed.

RESULTS

Intraperitoneal ketamine up to 3.75 mg kg(-1) caused no sedative or antinociceptive effects and intrathecal ketamine caused dose-dependent, spinally mediated antinociceptive effects. Injections of ketamine doses that caused no antinociceptive effects when given alone (intrathecal 25 microg and intraperitoneal 3.75 mg/kg) significantly increased spinally mediated antinociception produced by intrathecal fentanyl injections when assessed using noxious heat (tail-flick test) but not when assessed by noxious electrical current (electrical current threshold test).

CONCLUSIONS

We conclude that ketamine can potentiate the effects of fentanyl by an interaction at the level of the spinal cord even when ketamine is given via a non-spinal route of administration.

Для цитирования: Nadeson R, Tucker A, Bajunaki E, Goodchild C S. Potentiation by ketamine of fentanyl antinociception. I. An experimental study in rats showing that ketamine administered by non-spinal routes targets spinal cord antinociceptive systems.. British journal of anaesthesia. 2002. DOI: 10.1093/bja/88.5.685.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.