Comparison of Subjective Image Quality of Mobile C-Arms Equipped with a-Si, CMOS or IGZO Flat-Panel Detectors for Intraoperative Fluoroscopy.

Brunken Fenna, Bullert Benno, Brauweiler Robert, Grützner Paul A, Vetter Sven Y, Beisemann Nils

СтатьяПеревод в очереди

Аннотация

Different flat-panel detector technologies are available for intraoperative fluoroscopy. This study compared orthopedic and trauma surgeons' preference and subjective image quality among mobile C-arm systems equipped with amorphous silicon (a-Si), complementary metal oxide semiconductor (CMOS) or indium gallium zinc oxide (IGZO) detectors. Fluoroscopic imaging was performed on four human specimens at four anatomic locations at pulse rates of 1/s and 10/s in low- and high-dose settings using three C-arm systems. Subjective image quality was rated by two observers on 5-point Likert scales. Pairwise forced-choice comparisons of images with identical acquisition parameters were analyzed using a Bradley-Terry model. Across all images, CMOS- and IGZO-based systems were preferred over the a-Si-based system in 91.8% and 90.4% of comparisons, respectively (ORs 9.53 and 11.20; both p < 0.001). No significant overall preference was observed between the IGZO- and CMOS-equipped systems. Subjective image quality ratings were significantly higher for CMOS- and IGZO-based systems compared with the a-Si-based system, particularly for overall image quality and perceived noise, while no consistent differences in image quality were found between CMOS- and IGZO-based systems. Overall, the CMOS- and IGZO-based systems evaluated in this study were preferred over the a-Si-based system and achieved superior subjective image quality ratings.

Для цитирования: Brunken Fenna, Bullert Benno, Brauweiler Robert, Grützner Paul A, Vetter Sven Y, Beisemann Nils. Comparison of Subjective Image Quality of Mobile C-Arms Equipped with a-Si, CMOS or IGZO Flat-Panel Detectors for Intraoperative Fluoroscopy.. Journal of imaging. 2026. DOI: 10.3390/jimaging12080337.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.