DOI 10.3390/s24175626

Медицинская библиотека · Sensors (Basel, Switzerland) · 2024

Comparing Device-Generated and Calculated Bioimpedance Variables in Community-Dwelling Older Adults.

Lafontant Kworweinski, Sterner Danielle A, Fukuda David H, Stout Jeffrey R, Park Joon-Hyuk, Thiamwong Ladda

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

Despite BIA emerging as a clinical tool for assessing older adults, it remains unclear how to calculate whole-body impedance (Z), reactance (Xc), resistance (R), and phase angle (PhA) from segmental values using modern BIA devices that place electrodes on both sides of the body. This investigation aimed to compare both the whole-body and segmental device-generated phase angle (PhADG) with the phase angle calculated using summed Z, Xc, and R from the left, right, and combined sides of the body (PhACalc) and to compare bioelectric variables between sides of the body. A sample of 103 community-dwelling older adults was assessed using a 50 kHz direct segmental multifrequency BIA device. Whole-body PhACalc values were assessed for agreement with PhADG using 2.5th and 97.5th quantile nonparametric limits of agreement and Spearman's rho. Bioelectrical values between sides of the body were compared using Wilcoxon rank and Spearman's rho. A smaller mean difference was observed between PhADG and right PhACalc (-0.004°, p = 0.26) than between PhACalc on the left (0.107°, p = 0.01) and on the combined sides (0.107°, p < 0.001). The sum of Z, R, and PhACalc was significantly different (p < 0.01) between the left (559.66 ± 99.55 Ω, 556.80 ± 99.52 Ω, 5.51 ± 1.5°, respectively) and the right sides (554.60 ± 94.52 Ω, 552.02 ± 94.23 Ω, 5.41 ± 0.8°, respectively). Bilateral BIA values do not appear to be interchangeable when determining whole-body measurements. Present data suggest that using right-sided segmental values would be the most appropriate choice for calculating whole-body bioelectrical variables.

Для цитирования: Lafontant Kworweinski, Sterner Danielle A, Fukuda David H, Stout Jeffrey R, Park Joon-Hyuk, Thiamwong Ladda. Comparing Device-Generated and Calculated Bioimpedance Variables in Community-Dwelling Older Adults.. Sensors (Basel, Switzerland). 2024. DOI: 10.3390/s24175626.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.