Медицинская библиотека · American journal of ophthalmology · 2019

Evaluation of a Multiplex Strip PCR Test for Infectious Uveitis: A Prospective Multicenter Study.

Nakano Satoko, Tomaru Yasuhiro, Kubota Toshiaki, Takase Hiroshi, Mochizuki Manabu, Shimizu Norio, Sugita Sunao, Strip PCR Project Group

Сравнительное исследованиеСтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: A novel multiplex polymerase chain reaction (PCR) test (Strip PCR) for 24 common ocular infectious disease pathogens was established. Solid-phase techniques provide stable, prompt, and accurate results while using less sample amount with lower cost than conventional quantitative real-time PCR (qPCR). Strip PCR for infectious uveitis was optimized and evaluated using intraocular samples.

DESIGN

Evaluation of diagnostic testing.

METHODS

We examined 722 samples at 14 institutions. Genomic DNA from aqueous humor and vitreous fluid was analyzed by qPCR and Strip PCR. Clinical diagnosis was determined based on symptoms, clinical findings, and laboratory tests. MainOutcomeMeasures: The diagnostic parameters of the Strip PCR were based on qPCR results.

RESULTS

Strip PCR showed low intra- and inter-institutional variability even when performed by technicians with various PCR skill levels. The targets of Strip PCR for infectious uveitis were optimized for 9 major pathogens (herpes simplex virus [HSV] 1, HSV2, varicella-zoster virus, human T-cell lymphotropic virus 1, human herpesvirus 6, Epstein-Barr virus, cytomegalovirus, Toxoplasma gondii, and Treponema pallidum) with 772 intraocular samples. The Strip PCR successfully detected pathogen DNA at concentrations ranging from 100 to 109 copies/mL in 252 of the 255 qPCR-positive samples. It yielded negative results for all the 191 qPCR-negative samples. Strip PCR had higher sensitivity (98.8%), specificity (98.5%), positive predictive value (98.8%), and negative predictive value (98.5%) than qPCR, with distinct primers. The Strip PCR results had strong correlation with that of the qPCR (r = 0.838) and they were consistent with the clinical diagnosis.

CONCLUSIONS

Easy-to-use Strip PCR is recommended for rapid diagnosis of infectious uveitis, as its results are equivalent to that of conventional qPCR.

Для цитирования: Nakano Satoko, Tomaru Yasuhiro, Kubota Toshiaki, Takase Hiroshi, Mochizuki Manabu, Shimizu Norio, Sugita Sunao, Strip PCR Project Group. Evaluation of a Multiplex Strip PCR Test for Infectious Uveitis: A Prospective Multicenter Study.. American journal of ophthalmology. 2019. DOI: 10.1016/j.ajo.2019.10.031.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.