DOI 10.1186/s12984-024-01346-5

Медицинская библиотека · Journal of neuroengineering and rehabilitation · 2024

Validity of an android device for assessing mobility in people with chronic stroke and hemiparesis: a cross-sectional study.

Sánchez-Sánchez M Luz, Ruescas-Nicolau Maria-Arantzazu, Arnal-Gómez Anna, Iosa Marco, Pérez-Alenda Sofía, Cortés-Amador Sara

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Incorporating instrument measurements into clinical assessments can improve the accuracy of results when assessing mobility related to activities of daily living. This can assist clinicians in making evidence-based decisions. In this context, kinematic measures are considered essential for the assessment of sensorimotor recovery after stroke. The aim of this study was to assess the validity of using an Android device to evaluate kinematic data during the performance of a standardized mobility test in people with chronic stroke and hemiparesis.

METHODS

This is a cross-sectional study including 36 individuals with chronic stroke and hemiparesis and 33 age-matched healthy subjects. A simple smartphone attached to the lumbar spine with an elastic band was used to measure participants' kinematics during a standardized mobility test by using the inertial sensor embedded in it. This test includes postural control, walking, turning and sitting down, and standing up. Differences between stroke and non-stroke participants in the kinematic parameters obtained after data sensor processing were studied, as well as in the total execution and reaction times. Also, the relationship between the kinematic parameters and the community ambulation ability, degree of disability and functional mobility of individuals with stroke was studied.

RESULTS

Compared to controls, participants with chronic stroke showed a larger medial-lateral displacement (p = 0.022) in bipedal stance, a higher medial-lateral range (p < 0.001) and a lower cranio-caudal range (p = 0.024) when walking, and lower turn-to-sit power (p = 0.001), turn-to-sit jerk (p = 0.026) and sit-to-stand jerk (p = 0.001) when assessing turn-to-sit-to-stand. Medial-lateral range and total execution time significantly correlated with all the clinical tests (p < 0.005), and resulted significantly different between independent and limited community ambulation patients (p = 0.042 and p = 0.006, respectively) as well as stroke participants with significant disability or slight/moderate disability (p = 0.024 and p = 0.041, respectively).

CONCLUSION

This study reports a valid, single, quick and easy-to-use test for assessing kinematic parameters in chronic stroke survivors by using a standardized mobility test with a smartphone. This measurement could provide valid clinical information on reaction time and kinematic parameters of postural control and gait, which can help in planning better intervention approaches.

Для цитирования: Sánchez-Sánchez M Luz, Ruescas-Nicolau Maria-Arantzazu, Arnal-Gómez Anna, Iosa Marco, Pérez-Alenda Sofía, Cortés-Amador Sara. Validity of an android device for assessing mobility in people with chronic stroke and hemiparesis: a cross-sectional study.. Journal of neuroengineering and rehabilitation. 2024. DOI: 10.1186/s12984-024-01346-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.