MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/s24041163

Медицинская библиотека · Sensors (Basel, Switzerland) · 2024

Incorporating Wearable Technology for Enhanced Rehabilitation Monitoring after Hip and Knee Replacement.

Lebleu Julien, Daniels Kim, Pauwels Andries, Dekimpe Lucie, Mapinduzi Jean, Poilvache Hervé, Bonnechère Bruno

СтатьяПеревод в очереди

Аннотация

Osteoarthritis (OA) poses a growing challenge for the aging population, especially in the hip and knee joints, contributing significantly to disability and societal costs. Exploring the integration of wearable technology, this study addresses the limitations of traditional rehabilitation assessments in capturing real-world experiences and dynamic variations. Specifically, it focuses on continuously monitoring physical activity in hip and knee OA patients using automated unsupervised evaluations within the rehabilitation process. We analyzed data from 1144 patients who used a mobile health application after surgery; the activity data were collected using the Garmin Vivofit 4. Several parameters, such as the total number of steps per day, the peak 6-minute consecutive cadence (P6MC) and peak 1-minute cadence (P1M), were computed and analyzed on a daily basis. The results indicated that cadence-based measurements can effectively, and earlier, differ among patients with hip and knee conditions, as well as in the recovery process. Comparisons based on recovery status and type of surgery reveal distinctive trajectories, emphasizing the effectiveness of P6MC and P1M in detecting variations earlier than total steps per day. Furthermore, cadence-based measurements showed a lower inter-day variability (40%) compared to the total number of steps per day (80%). Automated assessments, including P1M and P6MC, offer nuanced insights into the patients' dynamic activity profiles.

Для цитирования: Lebleu Julien, Daniels Kim, Pauwels Andries, Dekimpe Lucie, Mapinduzi Jean, Poilvache Hervé, Bonnechère Bruno. Incorporating Wearable Technology for Enhanced Rehabilitation Monitoring after Hip and Knee Replacement.. Sensors (Basel, Switzerland). 2024. DOI: 10.3390/s24041163.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.