MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/17483107.2019.1683239

Медицинская библиотека · Disability and rehabilitation. Assistive technology · 2019

BCI controlled robotic arm as assistance to the rehabilitation of neurologically disabled patients.

Casey Anthony, Azhar Hannan, Grzes Marek, Sakel Mohamed

СтатьяПеревод в очереди

Аннотация

PURPOSE: Brain-computer interface (BCI)-controlled assistive robotic systems have been developed with increasing success with the aim to rehabilitation of patients after brain injury to increase independence and quality of life. While such systems may use surgically implanted invasive sensors, non-invasive alternatives can be better suited due to the ease of use, reduced cost, improvements in accuracy and reliability with the advancement of the technology and practicality of use. The consumer-grade BCI devices are often capable of integrating multiple types of signals, including Electroencephalogram (EEG) and Electromyogram (EMG) signals.

MATERIALS AND

METHODS

This paper summarizes the development of a portable and cost-efficient BCI-controlled assistive technology using a non-invasive BCI headset "OpenBCI" and an open source robotic arm, U-Arm, to accomplish tasks related to rehabilitation, such as access to resources, adaptability or home use. The resulting system used a combination of EEG and EMG sensor readings to control the arm. To avoid risks of injury while the device is being used in clinical settings, appropriate measures were incorporated into the software control of the arm. A short survey was used following the system usability scale (SUS), to measure the usability of the technology to be trialed in clinical settings.

RESULTS

From the experimental results, it was found that EMG is a very reliable method for assistive technology control, provided that the user specific EMG calibration is done. With the EEG, even though the results were promising, due to insufficient detection of the signal, the controller was not adequate to be used within a neurorehabilitation environment. The survey indicated that the usability of the system is not a barrier for moving the system into clinical trials.Implication on rehabilitationFor the rehabilitation of patients suffering from neurological disabilities (particularly those suffering from varying degrees of paralysis), it is necessary to develop technology that bypasses the limitations of their condition. For example, if a patient is unable to walk due to the unresponsiveness in their motor neurons, technology can be developed that used an alternate input to move an exoskeleton, which enables the patient to walk again with the assistance of the exoskeleton.This research focuses on neuro-rehabilitation within the framework of the NHS at the Kent and Canterbury Hospital in UK. The hospital currently does not have any system in place for self-driven rehabilitation and instead relies on traditional rehabilitation methods through assistance from physicians and exercise regimens to maintain muscle movement.This paper summarises the development of a portable and cost-efficient BCI controlled assistive technology using a non-invasive BCI headset "OpenBCI" and an open source robotic arm, U-Arm, to accomplish tasks related to rehabilitation, such as access to resources, adaptability or home use. The resulting system used a combination of EEG and EMG sensor readings to control the arm, which could perform a number of different tasks such as picking/placing objects or assist users in eating.

Для цитирования: Casey Anthony, Azhar Hannan, Grzes Marek, Sakel Mohamed. BCI controlled robotic arm as assistance to the rehabilitation of neurologically disabled patients.. Disability and rehabilitation. Assistive technology. 2019. DOI: 10.1080/17483107.2019.1683239.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.