MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/jcm14113856

Медицинская библиотека · Journal of clinical medicine · 2025

Use of Prophylactic Methylxanthines to Prevent Extubation Failure in Preterm Neonates with a Birth Weight of 1250-2499 g: A Propensity Score-Matched Analysis.

Suwankomonkul Pachima, Thatrimontrichai Anucha, Pakhathirathien Pattima, Praditaukrit Manapat, Maneenil Gunlawadee, Dissaneevate Supaporn, Trangkhanon Chamaiporn, Phon-In Neeracha

СтатьяПеревод в очереди

Аннотация

Background/

Objectives

Preterm neonates with a birth weight (BW) of 500-1250 g who receive prophylactic methylxanthine have a lower rate of bronchopulmonary dysplasia and neurodevelopmental disability than their counterparts. In a meta-analysis of previous studies (published during 1985-1993, with no routine continuous positive airway pressure), extubation failure rates in preterm neonates with BW < 2500 g who received and did not receive methylxanthine were 25.0% and 50.6%, respectively (risk difference, -0.27; 95% confidence interval [CI], -0.39 to -0.15). However, no study to date has assessed the effects of prophylactic methylxanthine use on endotracheal extubation in infants weighing 1250-2499 g until now.

Methods

First-time extubation was compared between 1:1 propensity score-matched methylxanthine and non-methylxanthine groups from a retrospective cohort of 541 neonates (born during 2014-2024).

Results

The domains from the overall cohort and propensity-matched data included 541 and 192 neonates, respectively. In the propensity score-matched sample, the mean gestational age and BW were 30.9 ± 1.9 weeks and 1584 ± 273 g, respectively. The median 5-min Apgar score was 9 (range of 7-9). Extubation failure within 7 days occurred in 10 (10.4%) and 13 (13.5%) neonates in the methylxanthine (n = 96) and non-methylxanthine (n = 96) groups, respectively, with a risk difference (95% CI) of -0.03 (-0.12 to 0.06), p = 0.50, and hazard ratio (95% CI) of 0.76 (0.33 to 1.72), p = 0.51.

Conclusions

In the current era with new non-invasive ventilation approaches, extubation failure in preterm neonates with a BW of 1250-2499 g is not significantly affected by the use of methylxanthine.

Для цитирования: Suwankomonkul Pachima, Thatrimontrichai Anucha, Pakhathirathien Pattima, Praditaukrit Manapat, Maneenil Gunlawadee, Dissaneevate Supaporn, Trangkhanon Chamaiporn, Phon-In Neeracha. Use of Prophylactic Methylxanthines to Prevent Extubation Failure in Preterm Neonates with a Birth Weight of 1250-2499 g: A Propensity Score-Matched Analysis.. Journal of clinical medicine. 2025. DOI: 10.3390/jcm14113856.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.