Closed-Perfusion Transretinal ERG Setup for Preclinical Drug and Nanostructure Testing.

Saeid Sama, Pitkanen Marja, Ilonen Emma, Niskanen Jukka, Tenhu Heikki, Vinberg Frans, Koskelainen Ari

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

The isolated mammalian retina may serve as a sensitive biosensor for preclinical drug testing, including eye drugs and a broader range of pharmaceuticals. To facilitate testing with minimal amounts of drug molecules or nanostructures, we developed a closed-perfusion transretinal electroretinography (tERG) setup.

METHODS

The major challenge with small amounts of circulating perfusate was maintaining retinal viability and stability during long experiments. We conducted ex vivo tERG using WT C57BL/6J and mice to assess rod- and cone-mediated light signals. The dark-adapted retina was stimulated with full-field light flashes while perfused at 5-6 ml/min.

RESULTS

The minimum perfusate needed in our closed-circulation was around 50 ml. Penicillin-Streptomycin (Pen-Strep) was indispensable for long recordings. Rod responses remained stable for at least 42 hours, the longest recording we conducted, with the retina still responsive, and rod and cone bipolar cell responses for up to 12 hours. IBMX (3-isobutyl-1-methylxanthine), a non-specific phosphodiesterase (PDE) inhibitor with reversible effects, validated our setup. We used our setup to test the zwitterionic polymer poly(sulfobetaine methacrylate) (PSMBA), serving as a promising material for thermoresponsive nanostructures, and the corresponding monomer SBMA for possible harmful effects on mouse rod and bipolar cell functioning.

CONCLUSION

Our closed-perfusion tERG setup enables long experiments with small amounts of perfusate. PSMBA or SBMA had no effect on rod and bipolar cell responses.

SIGNIFICANCE: This method is applicable for assessing drug functionality, as well as conducting preliminary biocompatibility and toxicity testing using small amounts of molecules or nanostructures that could impact neuronal or synaptic function.

Для цитирования: Saeid Sama, Pitkanen Marja, Ilonen Emma, Niskanen Jukka, Tenhu Heikki, Vinberg Frans, Koskelainen Ari. Closed-Perfusion Transretinal ERG Setup for Preclinical Drug and Nanostructure Testing.. IEEE transactions on bio-medical engineering. 2025. DOI: 10.1109/tbme.2024.3493616.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.