MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jchromb.2009.12.019

Медицинская библиотека · Journal of chromatography. B, Analytical technologies in the biomedical and life sciences · 2009

Quantification of theobromine and caffeine in saliva, plasma and urine via liquid chromatography-tandem mass spectrometry: a single analytical protocol applicable to cocoa intervention studies.

Ptolemy Adam S, Tzioumis Emma, Thomke Arjun, Rifai Sami, Kellogg Mark

Клиническое исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Targeted analyses of clinically relevant metabolites in human biofluids often require extensive sample preparation (e.g., desalting, protein removal and/or preconcentration) prior to quantitation. In this report, a single ultra-centrifugation based sample pretreatment combined with a designed liquid chromatography-tandem mass spectrometry (LC-MS/MS) protocol provides selective quantification of 3,7-dimethylxanthine (theobromine) and 1,3,7-trimethylxanthine (caffeine) in human saliva, plasma and urine samples. The optimized chromatography permitted elution of both analytes within 1.3 min of the applied gradient. Positive-mode electrospray ionization and a triple quadruple MS/MS instrument operated in multiple reaction mode were used for detection. (13)C(3) isotopically labeled caffeine was included as an internal standard to improve accuracy and precision. Implementing a 20-fold dilution of the isolated low MW biofluid fraction prior to injection effectively minimized the deleterious contributions of all three matrices to quantitation. The assay was linear over a 160-fold concentration range from 2.5 to 400 micromol L(-1) for both theobromine (average R(2) 0.9968) and caffeine (average R(2) 0.9997) respectively. Analyte peak area variations for 2.5 micromol L(-1) caffeine and theobromine in saliva, plasma and urine ranged from 5 and 10% (intra-day, N=10) to 9 and 13% (inter-day, N=25) respectively. The intra- and inter-day precision of theobromine and caffeine elution times were 3 and <1% for all biofluids and concentrations tested. Recoveries for caffeine and theobromine ranged from 114 to 118% and 99 to 105% at concentration levels of 10 and 300 micromol L(-1). This validated protocol also permitted the relative saliva, plasma and urine distribution of both theobromine and caffeine to be quantified following a cocoa intervention.

Для цитирования: Ptolemy Adam S, Tzioumis Emma, Thomke Arjun, Rifai Sami, Kellogg Mark. Quantification of theobromine and caffeine in saliva, plasma and urine via liquid chromatography-tandem mass spectrometry: a single analytical protocol applicable to cocoa intervention studies.. Journal of chromatography. B, Analytical technologies in the biomedical and life sciences. 2009. DOI: 10.1016/j.jchromb.2009.12.019.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.