MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/00007691-200310000-00006

Медицинская библиотека · Therapeutic drug monitoring · 2003

A rapid and simultaneous determination of several analgesic antiinflammatory agents by capillary zone electrophoresis.

Makino Kazutaka, Yano Takahisa, Maiguma Takayoshi, Teshima Daisuke, Sendo Toshiaki, Itoh Yoshinori, Oishi Ryozo

СтатьяПеревод в очереди

Аннотация

A rapid and simultaneous determination of several analgesic antiinflammatory agents--ibuprofen, acetaminophen, indomethacin, and salicylic acid--in human serum was developed by using capillary zone electrophoresis (CZE) coupled with diode-array ultraviolet detection. After precipitation of serum protein with acetonitrile containing 3-isobutyl-1-methylxanthine as the internal standard, an aliquot of deproteinized samples was applied directly to the CZE system. It enabled us to measure all of these four agents within 6 min, and there were no peaks interfering with the assay of these agents or 3-isobutyl-1-methylxanthine. Both the separation and quantification of these agents in human serum were reproducible after repeated analysis within a day or day-to-day analysis. In addition, there was a good correlation for each drug (r = 0.997-0.999) between the values in serum determined by CZE analysis and those measured either by high-performance liquid chromatography with ultraviolet detection (ibuprofen and indomethacin) or by fluorescence polarization immunoassay (acetaminophen and salicylic acid). Therefore, the present CZE analysis could provide a simple, rapid, and efficient method for the identification as well as monitoring of analgesic antiinflammatory agents, particularly in serum of patients suffering from intoxication by overdosage of these agents.

Для цитирования: Makino Kazutaka, Yano Takahisa, Maiguma Takayoshi, Teshima Daisuke, Sendo Toshiaki, Itoh Yoshinori, Oishi Ryozo. A rapid and simultaneous determination of several analgesic antiinflammatory agents by capillary zone electrophoresis.. Therapeutic drug monitoring. 2003. DOI: 10.1097/00007691-200310000-00006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.