DOI 10.1016/j.ejso.2011.02.002
Pain experienced by patients during minimal-invasive ultrasound-guided breast biopsy: vacuum-assisted vs core-needle procedure.
Аннотация
AIMS: To evaluate comparatively the pain associated with ultrasound-guided core-needle (CN) and vacuum-assisted (VA) biopsy for non-palpable breast lesions.
METHODS
723 women undergoing ultrasound-guided breast biopsy for BIRADS IV and V lesions according to the same standardised protocol were prospectively studied. 14-gauge CN biopsy with an automated gun was performed in 321 patients. In 402 women biopsy was made using 11-gauge VA hand-held probe. Immediately after the procedure patients were interviewed about the pain experienced during the biopsy and were asked to indicate at the pain intensity on a eleven-point scale: from 0 (none) to 10 (extreme, worst possible pain).
RESULTS
The median rate of pain experienced by women during biopsy was 4 (range 2-7). There were no significant differences between CN and VA groups with regard to age, body mass index, menopausal status, history of parity, hormone replacement therapy, menopausal status, breast parenchymal pattern (according to Wolfe's classification), family history of breast cancer, lesion size and number of samples. CN biopsy with an automated gun was significantly more painful (P < 0.01) than procedure with VA hand-held device as evaluated by patients: median 6 (4-7) vs 3 (2-5), respectively.
CONCLUSIONS
Despite using the larger needle VA procedure results in less pain experienced by women in comparison to CN biopsy with automated gun. Reduced patient discomfort should be one of the reasons for the preferential use of VA biopsy in the assessment of non-palpable breast masses.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.