MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1158/1055-9965.epi-04-0165

Медицинская библиотека · Cancer epidemiology, biomarkers & prevention : a publication of the American Association for Cancer Research, cosponsored by the American Society of Preventive Oncology · 2005

Hormone replacement therapy, percent mammographic density, and sensitivity of mammography.

Kavanagh Anne M, Cawson Jennifer, Byrnes Graham B, Giles Graham G, Marr Georgina, Tong Bin, Gertig Dorota M, Hopper John L

СтатьяПоддержка исследования: вне правительства СШАВалидационное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

We examine to what extent the lower mammographic sensitivity found in hormone replacement therapy (HRT) users can be explained by any association of HRT use with higher mammographic density and more difficult to detect cancers.

METHODS

We used logistic regression to estimate the odds of a false-negative screen (a breast cancer diagnosed in the 24 months after a negative screening examination) for HRT users and to estimate, and adjust for, mammographic density (measured on a continuous scale, blinded, using a reliable, computer-assisted method), tumor characteristics (size, grade, and morphology), and potential confounders (age, symptom status, family history, and prior screening) among women ages > or =55 years who attended BreastScreen Victoria for first round screening mammography in 1994 and 1995 (1,086 breast cancers) and for subsequent round screening (471 breast cancers) in 1995 and 1996.

RESULTS

After adjusting for confounders, HRT users were more likely to have a false-negative screen [first round: odds ratio (OR), 1.99; 95% confidence interval (95% CI), 1.4-2.9; subsequent round: OR, 2.29; 95% CI, 1.4-3.8]. This effect was modestly attenuated by adjusting for mammographic density (first round: OR, 1.54; 95% CI, 1.0-2.3; subsequent round: OR, 1.97; 95% CI, 1.2-3.3). Adjusting for tumor characteristics resulted in a modest increase in the odds of a false negative at first round but had no effect at subsequent round.

CONCLUSIONS

Mammographic density only partly explains the effect of HRT on sensitivity. Further research needs to clarify whether hyperemic breast tissue changes affect cancer detectability in HRT users as well as the possibility that the quality of mammography may be poor in some HRT users.

Для цитирования: Kavanagh Anne M, Cawson Jennifer, Byrnes Graham B, Giles Graham G, Marr Georgina, Tong Bin, Gertig Dorota M, Hopper John L. Hormone replacement therapy, percent mammographic density, and sensitivity of mammography.. Cancer epidemiology, biomarkers & prevention : a publication of the American Association for Cancer Research, cosponsored by the American Society of Preventive Oncology. 2005. DOI: 10.1158/1055-9965.epi-04-0165.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.