MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1063/5.0345285

Медицинская библиотека · The Review of scientific instruments · 2026

Development of an ultrahigh-vacuum-compatible cryogen-free scanning nitrogen-vacancy magnetometer.

Jiao Sihai, Wang Chunzheng, Zheng Haoran, Wang Zhongjie, Guo Maosen, Zhu Changjiang, Gao Chunlei

СтатьяПеревод в очереди

Аннотация

Scanning nitrogen-vacancy (NV) magnetometry has emerged as a powerful technique for nanoscale magnetic imaging owing to its high spatial resolution, high magnetic sensitivity, and noninvasive optical readout. For low-temperature operation, existing scanning NV microscopes have been implemented in different cryogenic systems, including liquid-helium cryostats and closed-cycle refrigerators. However, ultrahigh-vacuum compatibility and in situ sample/probe exchange remain largely unavailable in these systems, hindering measurements on pristine and surface-sensitive quantum materials. Here, we report a cryogen-free ultrahigh-vacuum scanning nitrogen-vacancy microscope equipped with an in-vacuum three-axis vector superconducting magnet, reaching a base pressure of 2 × 10-10 Torr and sample temperatures down to 2 K. The system enables in situ exchange and separate temperature control of both the sample and the probe. A pillar-array diamond probe architecture is implemented to provide flexible selection of NV centers with different crystallographic orientations, allowing access to complementary magnetic-field projections of a single spin texture. System performance is verified through thermal characterization, single-NV characterization, NV-sample distance calibration, and magnetic imaging demonstrations, which include imaging the same skyrmion bubble with two nitrogen-vacancy centers of different orientations in CoFeB and resolving individual superconducting vortices in bulk NbSe2.

Для цитирования: Jiao Sihai, Wang Chunzheng, Zheng Haoran, Wang Zhongjie, Guo Maosen, Zhu Changjiang, Gao Chunlei. Development of an ultrahigh-vacuum-compatible cryogen-free scanning nitrogen-vacancy magnetometer.. The Review of scientific instruments. 2026. DOI: 10.1063/5.0345285.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.